CONCEPTUAL DESIGN January 9, 2009<br />

<strong>Emeryville</strong> <strong>Center</strong> <strong>of</strong> <strong>Community</strong> <strong>Life</strong><br />

Ro<strong>of</strong> – minimum R-30 – provide rigid insulation above metal ro<strong>of</strong> decking at new gym<br />

and multi-purpose room, foil faced batt insulation between framing members at other<br />

areas.<br />

Exterior walls - minimum R-19 –batt insulation<br />

4. Provide 3-1/2” thick acoustical insulation batts in the interior walls separating toilet<br />

rooms from adjacent spaces, and at all walls for activity rooms, <strong>of</strong>fices, and other<br />

sound sensitive spaces.<br />

5. Provide 1” thick tectum panels, 8’ high by 8’ wide in a band around upper walls at all<br />

four sides <strong>of</strong> the gymnasium.<br />

6. No materials with formaldehyde content shall be utilized for this project.<br />

Section 07270: Firestopping<br />

1. Provide mineral wool batts for fire safing insulation where required at occupancy or area<br />

separations.<br />

Section 07412: Manufactured Metal Ro<strong>of</strong>ing<br />

1. Pre-formed metal ro<strong>of</strong>ing system at gym and upper multi-purpose room ro<strong>of</strong>s,<br />

complete with anchoring assembly and accessory components for complete secure<br />

installation. Berridge, AEP-span or equal. Color to conform with LEED cool ro<strong>of</strong><br />

requirements.<br />

2. Complete with integral shop finished flashing and sheet metal trim.<br />

Section 07415: Manufactured Metal Wall Panels<br />

1. Factory formed metal wall panel siding where indicated on exterior elevations,<br />

including framing/anchorage assembly, and accessory components.<br />

2. To be <strong>of</strong> not less than 22 gage galvanized steel, with Kynar 500 or equal factory<br />

installed fluoropolymer finish. Color to be selected, smooth finish.<br />

3. Include all related metal trim, including coping and ornamental trim at high walls.<br />

Section 07500: Single-ply Ro<strong>of</strong>ing<br />

1. Flat or low sloping ro<strong>of</strong>s to be single-ply PVC with minimum reflectance and emissivity<br />

as required for LEED reflective ro<strong>of</strong> credit. Tremco or equivalent.<br />

2. Installation as recommended by manufacturer over approved substrate.<br />

Outline Specifications- 40