CONCEPTUAL DESIGN January 9, 2009<br />

<strong>Emeryville</strong> <strong>Center</strong> <strong>of</strong> <strong>Community</strong> <strong>Life</strong><br />

3. Provide flashing and counterflashing at all mechanical equipment curbs, ro<strong>of</strong><br />

expansion joints and penetrations per manufacturer’s details.<br />

4. Provide flashing with metal counterflashing set into reglet at ro<strong>of</strong>/wall intersections per<br />

manufacturer’s details.<br />

5. Provide manufacturers recommended walking surfaces for access to all ro<strong>of</strong>top<br />

equipment.<br />

Section 07550: Occupied Ro<strong>of</strong> Decks<br />

1. A number <strong>of</strong> buildings, including the lower grade classroom building, have occupied<br />

ro<strong>of</strong> decks for playground or other uses.<br />

2. At playground areas, the deck should be recycled rubber pavers over setting bed over<br />

ro<strong>of</strong> waterpro<strong>of</strong>ing membrane.<br />

3. At other ro<strong>of</strong> decks, it should be precast pavers over setting bed over waterpro<strong>of</strong>ing<br />

membrane.<br />

Section 07560: Living Ro<strong>of</strong><br />

3. Portions <strong>of</strong> the ro<strong>of</strong>, over the upper multi-purpose room and perhaps other smaller<br />

areas, are to be provided with living green ro<strong>of</strong>s.<br />

4. Manufacturer to be Tremco, GAF or other sustainable ro<strong>of</strong> company.<br />

Section 07620: Sheet Metal Flashing and Trim<br />

1. All exterior gutters, downspouts, rake trim, flashing caps is to be <strong>of</strong> 20 ga. Galvanized<br />

sheet metal with paint finish.<br />

2. S<strong>of</strong>fits, ro<strong>of</strong> overhangs at eaves and gable ends, miscellaneous ro<strong>of</strong> vents to be<br />

galvanized sheet metal with painted finish.<br />

Section 07900: Sealants and Caulking<br />

1. All exterior materials are to be selected to withstand the climatic conditions <strong>of</strong> the site.<br />

2. Concealed sealants for bedding <strong>of</strong> sills or other non-visible areas to be one part, gun<br />

grade, non-sag, Tremco “Butyl Sealant” or equal.<br />

3. Exposed interior sealant to be Tremco “Mono” acrylic sealant or equal, with color to<br />

match primary adjacent surface finish color.<br />

Outline Specifications- 41