(h)<br />

4. Safety Analysis<br />

(a)<br />

(b)<br />

(c)<br />

(d)<br />

Details of ventilation system for removal of noxious gases generated<br />

should be provided.<br />

This section should document the accident analysis, including any<br />

systematic methodology (i.e. failure mode and effects analysis, fault<br />

trees, etc.) used for the identification and mitigation of potential<br />

hazards.<br />

This section should discuss the methods used at the accelerator facility<br />

to control and mitigate the potential hazards.<br />

Analysis of design basis or postulated emergency conditions,<br />

including those due to natural or disruptive factors. Demonstration<br />

of adequacy of protective measures provided in the design.<br />

The residual risk to the facility, workers, the public, and the<br />

environment should be discussed.<br />

5. Accelerator Safety Envelope<br />

This section should provide the accelerator safety envelope (ASE) that will<br />

establish and define the limits of operation for the facility/operation.<br />

6. Quality Assurance<br />

This section should describe the quality assurance (QA) program to be applied<br />

to the accelerator facility (Give broad guidelines. In addition QA manual<br />

should be made separately as per Appendix 4F of AERB safety guide AERB/<br />

RF/SG/G-3)<br />

7. Decommissioning and Decontamination Plan<br />

A description of structural and internal features which would facilitate<br />

decommissioning and decontamination of the accelerator complex should be<br />

provided in this section. Waste management of radiological and hazardous<br />

material generation from the decommissioning and decontamination operation<br />

should be discussed. Provisions including adequate financial arrangement<br />

for safe disposal of spent/disused sources should be made.<br />

8. References/Glossary/Abbreviations<br />

In short, the FSAR (SAD) shall contain the following:<br />

(a)<br />

(b)<br />

A description of (or a reference to) the facility’s function, location,<br />

and management organisation, as well as details of major facility<br />

components and their operation.<br />

Hazards from both normal operation and credible accidents in the<br />

facility and associated onsite and offsite impacts to workers, the<br />

public, and the environment.<br />