Facility specific : Control console facility to view active and passive<br />
engineered controls<br />
Area radiation monitors<br />
Ventilation facility<br />
Caution and alert system<br />
Access sensors or interlocks: Electrical, magnetic and mechanical<br />
‘Crash’ or ‘Scram’ buttons either mounted on walls or at doors and<br />
gates<br />
Search and rescue control<br />
Warning indicators (status lights, alarms, posted procedures)<br />
10. Details of Documents with Details (to be submitted)<br />
Design detail : Summary of medical cyclotron design and general<br />
working principles, specifications and physical<br />
parameters of the system and user objectives.<br />
Site characteristics : Location, occupancy in site area as well as surrounding<br />
population up to 30 meters radius,<br />
geology, load bearing capacity of soil and rock,<br />
structural design criteria, foundation, meteorology,<br />
seismology, Water table, flood level, plinth level<br />
(with respect to nearest accessible road), AERB<br />
site approval reference, etc.<br />
Medical cyclotron : Description of general layout, details of buildings,<br />
pressure vessels, vacuum system, Radio frequency<br />
system, Magnetic field, beam injection, acceleration,<br />
transport and target system including their<br />
design, construction and testing and quality<br />
assurance manual for the equipment.<br />
Synthesis and<br />
dispensing units<br />
: Name and address of the manufacturer and<br />
supplier, make and model of the synthesis and<br />
dispensing unit, maximum activity to be handled,<br />
material and thickness of shielding.<br />
Biological shield - Final sketch giving details of shielding wall<br />
surrounding the source, wall thickness, labyrinth<br />
access, openings, voids, reinforcements, embedment<br />
etc. in the biological shield. Method of<br />
shielding calculation and the dose limits followed<br />
182