(c)<br />

(d)<br />

Work planning and supervision<br />

Implementation of safety requirement during construction including<br />

fire safety and first aid<br />

Preventive maintenance and preservation of items in stores or installed should<br />

be carried out in accordance with manufacturers’ recommendations and good<br />

engineering practices, and documented.<br />

A.5 VERIFICATION FUNCTIONS<br />

A.5.1<br />

A.5.2<br />

A.5.3<br />

Verification Programme<br />

A comprehensive documented verification programme to be prepared to assure<br />

conformance of construction of the PARF as per the relevant codes and<br />

standards. Verification programme should comprise external (third party) as<br />

well as internal verification at specified stages/periodicity.<br />

Inspection and Test Controls<br />

A plan for inspection and testing of the materials/components used for<br />

construction, should be established. These should include identification of<br />

characteristics to be checked, type of check, acceptance norms etc. These<br />

should specifically include:<br />

(a)<br />

(b)<br />

(c)<br />

Audit<br />

Inspection of soil rocks, earthworks and foundation piles<br />

Testing of concrete<br />

Inspection of civil and steel structures<br />

Provisions need to be prescribed detailing the establishment and<br />

implementation of a comprehensive system of planned and documented audits<br />

to verify the implementation and effectiveness of the various elements of the<br />

quality assurance programme. It should address the audit performance, audit<br />

personnel, audit plan and audit timing etc. The requirement for QA audit and<br />

extent of its application should be based on the safety significance of the<br />

system.<br />

A.6 CORRECTIVE FUNCTIONS<br />

A.6.1<br />

Non-conformity Control and Corrective Actions<br />

A system for the control of non-conformances and their corrective actions<br />

should be established. Non-conformances, deviations or inadequacies<br />

affecting quality should be identified and controlled. The persons responsible<br />

for review and disposition of non-conformances should be identified. The<br />

programme should provide that appropriate action be taken to ensure that<br />

167