OWS / OCM system:<br />

Familiarize yourself with the system main components.<br />

From which tanks is the OWS system processing?<br />

OCM system is locked /dedicated responsible person?<br />

Is the OCM system automated?<br />

The OCM system included alarm and three way valve “open / close” functions.<br />

Sample line from main discharge line to the OCM system. This is a small diameter line from the<br />

“inlet side “of the three way valve to the analyzer. This sample line is relatively short and has no<br />

valves / cocks.<br />

To discharge, oil ppm level are recorded this can be done:<br />

o Check “Writer card” / “strip charts”. From previous years feedback it appears that not<br />

much large vessels use the “writer / strip card option”.<br />

o Electronically / stored in the White box / relayed to the engine control room repeater<br />

system.<br />

o OCM data Read outs? Memory read out how is this done?<br />

o Recent alarms?<br />

o OCM system data can be read out local; however this requires to open the “white box<br />

cage”. In order to do so the responsible officer and C/E have to witness the opening and<br />

the reason for the opening. Some vessels do this for routine operations. This is the<br />

opportunity for the OR to witness.<br />

o Is memory storage history of “open box” Close box available? Ask for demonstration?<br />

o Are cards hard discs / repeater printing outs made of the OCM system?<br />

Some vessel had a defective (under repair) closed “sealed” OWS unit. Check the paperwork and<br />

the reporting to the USCG (when in USA waters).<br />

General condition of the three way valve, activator lines (pneumatic / electronic) attached?<br />

Electric cabling.<br />

Piping from the last stage OWS / OCM is relatively small diameter are bypassed or blind flanges<br />

installed? Some vessels made modifications Describe / check.<br />

OWS Citations:<br />