18.01.2015 Views

IP 55 Modular Cabinets

IP 55 Modular Cabinets

IP 55 Modular Cabinets

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SC-AH; AIR TO WATER HEAT EXCHANGERS<br />

Fig. 169.1<br />

Note:<br />

The note relative to power yield is the<br />

same in CF-P and CST conditioners, with<br />

the difference that the specific yield in the<br />

table shown below refers to a temperature<br />

difference of 25°, respectively, between<br />

the cabinet temperature and the temperature<br />

of the water intake.<br />

SC-AH : DATA ON DESIGN CHARACTERISTICS<br />

CODE<br />

Fig. 169.2<br />

Fig. 169.2 - Example<br />

of operation of an Air<br />

to Water heat exchanger.<br />

Absorbed<br />

power<br />

SC - AH<br />

If the temperature inside the cabinet is<br />

less or equal to the outside temperature,<br />

it is possible to install an Air to Water<br />

heat exchanger, but connection to the<br />

water mains is necessary in this case.<br />

The structure is in RAL 70325 painted<br />

sheet metal, complete with a self-adhesive<br />

gasket; the system of condensation<br />

recovery and control; exchanger pack<br />

with aluminium fins and copper tubing,<br />

radial or axial fans on ball bearings, with<br />

internal thermal protection and a 3 m<br />

long power cable.<br />

Available on request:<br />

Adjustment thermostat with water electro<br />

valve.<br />

Power<br />

Absorbed<br />

Voltage<br />

Dimensions:<br />

H x W x D<br />

Weight<br />

W V - Hz A mm Kg<br />

SC - AH / 0656 35 230 - 50/60 0,21 404x308x114 9<br />

SC - AH / 1<strong>55</strong>6 80 230 - 50/60 0,36 925x400x205 20<br />

SC - AH / 2<strong>55</strong>6 80 230 - 50/60 0,38 925x400x205 21<br />

SC - AH / 5050 1<strong>55</strong> 230 - 50/60 0,7 1101x501x300 39<br />

SC - AH / 10056 310 230 - 50/60 1,4 2000x800x400 90<br />

SC - AH / 10050-4 310 400/440 - 50/60 0,8 2000x800x400 90<br />

SC - AH / 14000 170 230 - 50/60 0,78 2000x800x600 90<br />

SC - AH / 14000-4 170 400/440 - 50/60 0,5 2000x800x600 90<br />

CODE<br />

Loss of load<br />

Cabinet Cabinet<br />

Specific Fan Air Water Water<br />

Water<br />

on water<br />

Working side<br />

yield Capacity capacity pressure<br />

connection<br />

side<br />

limit protection<br />

Nose level<br />

W m 3 /h l/h kPa kPa inch °C <strong>IP</strong> dB(A)<br />

SC - AH / 0656 870 330 150 500 2 3/8 10 ÷ 50 <strong>IP</strong> <strong>55</strong> 58<br />

SC - AH / 1<strong>55</strong>6 2200 575 150 500 2 1/2 10 ÷ 50 <strong>IP</strong> <strong>55</strong> 58<br />

SC - AH / 2<strong>55</strong>6 3100 860 500 500 63 1/2 10 ÷ 50 <strong>IP</strong> <strong>55</strong> 58<br />

SC - AH / 5050 6700 1450 860 500 40 1/2 10 ÷ 50 <strong>IP</strong> <strong>55</strong> 58<br />

SC - AH / 10056 12500 2900 1440 800 90 3/4 10 ÷ 50 <strong>IP</strong> 54 60<br />

SC - AH / 10050-4 12500 2900 1440 800 90 3/4 10 ÷ 50 <strong>IP</strong> 54 60<br />

SC - AH / 14000 17500 2365 2520 600 121 3/4 10 ÷ 50 <strong>IP</strong> 54 76<br />

SC - AH / 14000-4 17500 2365 2520 600 121 3/4 10 ÷ 50 <strong>IP</strong> 54 76<br />

BOZZA DI STAMPA<br />

Note: The templates for the exchangers are supplied on request.<br />

21 CATALOGUE<br />

169

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!