ELECTROMAGNETIC COMPLIANCE<br />

TEST PERFORMANCE<br />

Attenuation (dB)<br />

Attenuation (dB)<br />

BOARD ATTENUATION H=2000 L=800 P=600<br />

Cabinet equipped with EMC clips<br />

Cabinet with zinc-coated internal<br />

faces and sealing edge, matched<br />

with shielded rubber gaskets.<br />

Standard cabinet<br />

Frequence (MHz)<br />

BOX ATTENUATION L=400 H=500 P=200<br />

Frequence (MHz)<br />

Box with zinc-coated internal faces<br />

and sealing edge, matched with<br />

shielded rubber gaskets.<br />

Standard box<br />

The shield efficiency tests on cabinets and metal boxes<br />

have been produced in compliance with specification 65-<br />

6 of American NSA concerning Military Standard MIL-<br />

STD-220.<br />

The first graph compares three different types of boards.<br />

Standard, equipped with EMC clips and fully zinc-coated<br />

cabinet.<br />

It is necessary to mention that the graph can vary dramatically<br />

according to the dimensions of the board and of<br />

the position of the detection. In the specific case, the<br />

detection has been performed on a spot on the back of<br />

the board at 1400 mm from floor and centered on the<br />

side.<br />

The second graph compares two cassettes: the first is a<br />

standard one and the second is fully zinc-coated<br />

In this case it is impossible to fully comply with NSA 65-<br />

6 standard, since the boxes are to small to maintain the<br />

required distance (30 cm) between the transmitting<br />

antenna and the wall of the tested box.<br />

According to the cabinet, an anecoic chamber has been<br />

employed.<br />

The detection indicated has been performed on the lower<br />

rear edges of the box.<br />

Interpretation of the measures<br />

To compare the noted attenuation, the following considerations<br />

must be taken into account:<br />

1. it is more difficult to shield a magnetic field instead of<br />

an electric one;<br />

2. at 50 Mhz the magetic field and the electric field<br />

almost coincide;<br />

3. at 50 Mhz the attenuations are lower due to a<br />

question of impendance (the electric wave and<br />

the magnetic wave match).<br />