Medspiration â System Requirements Document - Data User Element
Medspiration â System Requirements Document - Data User Element
Medspiration â System Requirements Document - Data User Element
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Medspiration</strong> MED-SOC-RS-001_1<br />
<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong> Issue F<br />
Page Table, fig. Reference ID Text from reference documents<br />
35 URD-099 Table 3.1.3.1 describes the consolidate user request for <strong>Medspiration</strong> data product ultra high resolution coverage based on<br />
SR entry<br />
PER.SYS.0080<br />
the user requirements set out in Section 2 of this document. All SST data products are requested to an accuracy of<br />
0.4K or better. The ECMWF request for data products having an accuracy of 0.1K is exceptionally demanding and should<br />
be considered as an “ultimate” target for satellite derived SST data products.<br />
36 T. 3.1.3.1 URD-100 Mediterranean Sea; L2P,SSTskin and SSTfnd SYS.0050<br />
SYS.0080<br />
36 T. 3.1.3.1 URD-101 Black Sea; L2P and`SSTfnd NASR<br />
36 T. 3.1.3.1 URD-102 Nordic seas; L2P, SSTskin, & SSTfnd NASR<br />
37 4 Product and Service Specifications<br />
37 4.1 Processing system<br />
37 URD-103 The system should generate the SST products as described in Tables 3.1.2.1 and 3.1.3.1. SYS.0050 to<br />
SYS.0083<br />
37 URD-104 In addition, <strong>Medspiration</strong> must contribute to the building of the GHRSST-PP Diagnostic <strong>Data</strong> Set as defined in [RD-2] and<br />
SYS.0070<br />
[RD-4].<br />
37 URD-105 The system should be extensible and flexible in order to accommodate new satellite sensors and the potential failure of<br />
EXP.SYS.0020<br />
others.<br />
37 URD-106 The <strong>Medspiration</strong> processing system must conform to the GHRSST-PP processing model [RD-3] if regional data products<br />
SYS.0020<br />
generated at different GHRSST-PP RDAC are to be effectively combined together as a single global coverage data<br />
product at GHRSST-PP GDAC.<br />
37 4.2 Input data definitions<br />
37 URD-107 The input data sets to the <strong>Medspiration</strong> data processing chain will be level 2 SST, wind speed and surface solar irradiance<br />
SYS.0030<br />
(SSI) data products that are available in real time.<br />
© 2004 SOC Page 109 of 193