30.01.2015 Views

Medspiration – System Requirements Document - Data User Element

Medspiration – System Requirements Document - Data User Element

Medspiration – System Requirements Document - Data User Element

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Medspiration</strong><br />

MED-SOC-RS-001_1<br />

<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong><br />

Issue F<br />

SR.L4A.0055/I The L4 processor shall provide a measure of diurnal variability of the skin<br />

deviation from SSTfnd within the data product time domain to accompany the SSTfnd<br />

estimate<br />

SR.L4A.0060/I The L2P data shall be selected/collated before the OI analysis<br />

The rules proposed for the collation of L2P data have to be more defined because they<br />

are completely correlated to the OI method. In particular, the rules proposed to collate the<br />

L2P data induce an averaging of them that is inconsistent with the formalism of the<br />

interpolation method. Consequently, the only collation possible will be into a 0.02° grid<br />

without any averaging. However, in most optimal analysis systems, the analysis itself will<br />

optimise the re-gridding of data although re-gridding prior to interpolation provides a more<br />

straightforward processing system (p 85 of the GDS, line410 of UR-IFREMER ).<br />

SR.L4A.0070/I The activation of the DV depends on the validation of the DV<br />

parameterisation in the Mediterranean sea that will be undertaken by the CNR team<br />

CNR will perform a study to verify the accuracy of the A Stuart-Menteth DV<br />

parameterisation in the Mediterranean sea. If results are satisfying, we will activate the<br />

DV parameterisation through the configuration file.<br />

SR.L4A.0080/I The L4A interpolation sub-module shall be based on the optimal<br />

interpolation scheme proposed by the GHRSST-PP (Reynolds et al., 2002, Guan and<br />

Kawamura, 2003)<br />

SR.L4A.0090/I OI scheme is expected to evolve as more experience is gained, therefore<br />

the L4 analysis system will be built in a modular manner<br />

SR.L4A.0095/I The regional parameters used by the OI scheme (correlation functions,<br />

spatial and temporal correlation radius) will come from the correlation study led by the<br />

CNR team in the frame of the <strong>Medspiration</strong> project.<br />

SR.L4A.0100/I The sub-module “products generation” will generate L4 SST fnd that<br />

contains SST fnd , 12 values of SST skin and associated errors. The SST skin values will be<br />

filled if the DV parameterisation is activated.<br />

© 2004 SOC Page 47 of 193