<strong>Medspiration</strong><br />
MED-SOC-RS-001_1<br />
<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong><br />
Issue F<br />
SR.INT.CTR.0030/I Remote systems (SOC, CMS) shall deliver to the controller the<br />
relevant error and operation messages to be centralized in the operation log system. The<br />
messages shall be transmitted through ftp.<br />
The IFREMER system controller will not have any direct control on remote systems (at<br />
SOC or CMS).The only interaction is through the operation and error messages.<br />
SR.INT.CTR.0040/I The controller shall deliver to the <strong>Medspiration</strong> remote systems the<br />
error and operation messages related to the dataflow control (retransmission request,<br />
acknowledgement). The messages shall be transmitted through ftp.<br />
SR.INT.CTR.0050/I Error and operation messages shall be formatted as specified in<br />
annex 4 (“Operation and error messages”).<br />
SR.INT.CTR.0060/I All systems under IFREMER control shall be able to return to the<br />
controller a return status after they have completed their task.<br />
4.2 External<br />
4.2.1 Satellite data providers<br />
SR.EXT.ING.0010/I The ingestion module shall query the provider to check the<br />
availability of data files from provider according to Table 5-1, Table 5-2 and Table 5-3<br />
SR.EXT.ING.0020/I The ingestion module shall download the available data files<br />
from data provider according to the protocol defined in Table 5-1, Table 5-2 and Table<br />
5-3<br />
SR.EXT.ING.0030/I Error message generated by the ingestion module shall be sent<br />
to the data provider and the system controller.<br />
SR.EXT.ING.0040/I The configuration files (see SR.QLC.0020 and SR.CFD.0370)<br />
will be received from GHRSST-PP by email (see SR.CFI.L2P.0010). They will be<br />
replaced manually after a coherency check.<br />
Comment: Configuration file format is still to be defined.<br />
SR.EXT.L2P.0010/I SSES will be provided by the GHRSST (see SR.CFI.L2P.0020)<br />
They will include a couple of error statistics (bias and standard deviation) per source and<br />
per confidence level value.<br />
Comment: The missing value to be used during the initiation phase remain to be defined.<br />