LowAODLimit, HighAODLimit and the corresponding maximum rejection rates will be set<br />
in a configuration file.<br />
3.2.4 Merging auxiliary data with SST<br />
SR.MRG.0010/I Generation of L2P shall extract auxiliary data (wind speed, surface solar<br />
irradiance and aerosol optical depth) and collocate with SST data.<br />
SR.MRG.0020/I The merging of auxiliary data (L2P-PP) must consist of a common preprocessing<br />
pixel based operation for Infra-red and microwave data.<br />
SR.MRG.0030/I The merging operation shall assign a fractional sea ice value if required<br />
(if no previous fractional sea ice exist in the data file).<br />
SR.MRG.0040/I The merging operation shall assign a wind speed value.<br />
SR.MRG.0050/I The merging operation shall assign a surface solar irradiance (SSI)<br />
value.<br />
SR.MRG.0060/I The merging operation shall assign an Atmospheric Optical Depth (AOD)<br />
value if required (if no previous AOD exist in the data file).<br />
SR.MRG.0070/I If an input data set pixel fractional sea ice estimate exists, this should be<br />
used to set the FractionalSeaIce flag of the L2P confidence data record.<br />
SR.MRG.0080/I If an input data set pixel sea ice flag exists (i.e. indicating sea ice but not<br />
the fractional amount of coverage), this should be used to set the FractionalSeaIce flag of<br />
the L2P confidence data record to 100%. If the flag is a binary flag, a check should be<br />
made against the reference fractional sea Ice data set to determine if the pixel is likely to<br />
be 100% contaminated and the fraction reported by the reference data set should be set<br />
if it is < 100%.<br />
SR.MRG.0090/I If an input data set pixel sea ice flag does not exist, and the pixel is<br />
located in or close to a region that may be ice contaminated, the reference sea ice data<br />
sets (NISE) or auxiliary (AMSRE-ICE) or NWP (NWP-ICE) fractional sea ice field should<br />
be used to determine the value of the L2P confidence flag FractionalSeaIce.<br />
SR.MRG.0110/I The L2P confidence variable FractionalSeaIce_source shall be set to<br />
indicate the data source used to set FractionalSeaIce. The code values are defined in<br />
[RD-3] Table 2.1.3.<br />