<strong>Medspiration</strong><br />

MED-SOC-RS-001_1<br />

<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong><br />

Issue F<br />

LowAODLimit, HighAODLimit and the corresponding maximum rejection rates will be set<br />

in a configuration file.<br />

3.2.4 Merging auxiliary data with SST<br />

SR.MRG.0010/I Generation of L2P shall extract auxiliary data (wind speed, surface solar<br />

irradiance and aerosol optical depth) and collocate with SST data.<br />

SR.MRG.0020/I The merging of auxiliary data (L2P-PP) must consist of a common preprocessing<br />

pixel based operation for Infra-red and microwave data.<br />

SR.MRG.0030/I The merging operation shall assign a fractional sea ice value if required<br />

(if no previous fractional sea ice exist in the data file).<br />

SR.MRG.0040/I The merging operation shall assign a wind speed value.<br />

SR.MRG.0050/I The merging operation shall assign a surface solar irradiance (SSI)<br />

value.<br />

SR.MRG.0060/I The merging operation shall assign an Atmospheric Optical Depth (AOD)<br />

value if required (if no previous AOD exist in the data file).<br />

SR.MRG.0070/I If an input data set pixel fractional sea ice estimate exists, this should be<br />

used to set the FractionalSeaIce flag of the L2P confidence data record.<br />

SR.MRG.0080/I If an input data set pixel sea ice flag exists (i.e. indicating sea ice but not<br />

the fractional amount of coverage), this should be used to set the FractionalSeaIce flag of<br />

the L2P confidence data record to 100%. If the flag is a binary flag, a check should be<br />

made against the reference fractional sea Ice data set to determine if the pixel is likely to<br />

be 100% contaminated and the fraction reported by the reference data set should be set<br />

if it is < 100%.<br />

SR.MRG.0090/I If an input data set pixel sea ice flag does not exist, and the pixel is<br />

located in or close to a region that may be ice contaminated, the reference sea ice data<br />

sets (NISE) or auxiliary (AMSRE-ICE) or NWP (NWP-ICE) fractional sea ice field should<br />

be used to determine the value of the L2P confidence flag FractionalSeaIce.<br />

SR.MRG.0110/I The L2P confidence variable FractionalSeaIce_source shall be set to<br />

indicate the data source used to set FractionalSeaIce. The code values are defined in<br />

[RD-3] Table 2.1.3.<br />