30.01.2015 Views

Medspiration – System Requirements Document - Data User Element

Medspiration – System Requirements Document - Data User Element

Medspiration – System Requirements Document - Data User Element

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Medspiration</strong> MED-SOC-RS-001_1<br />

<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong> Issue F<br />

Page Table, fig. Reference ID Text from reference documents<br />

37 URD-108 Table 4.2.1 provides a summary of the data streams that should be considered by the <strong>Medspiration</strong> data processing<br />

SR entry<br />

SYS.0030<br />

system. All of these data sets are available in real time and have either no data usage agreement or a special data<br />

agreement that has been negotiated for the GHRSST-PP project.<br />

37 URD-109 In some cases data providers have stipulated that all data must be used for the sole purpose of the GHRSST-PP. As<br />

SYS.0040<br />

37 4.3 <strong>Data</strong> products<br />

<strong>Medspiration</strong> intends to generate and disseminate combined L2 data products (as opposed to the native L2 data streams<br />

themselves) there are no data product dissemination limitations associated with use of these L2 data streams.<br />

3 URD-110 The <strong>Medspiration</strong> Project must be capable of insertion into the implementation strategy of GHRSSTPP, becoming a<br />

SYS.0010<br />

Regional <strong>Data</strong> Assembly Centre and capable of contributing regional coverage GHRSST-PP EURDAC area L2P data<br />

products (as defined in the GPM) to Global <strong>Data</strong> Analysis Centres in real time. In addition, European area coverage L4<br />

analysed data products should be produced to satisfy European user needs. The required data products are:<br />

37 URD-111 • Collated products (L2P) for each input sensor. L2P data products should be made available to European users in real<br />

time via special agreement. L2P data products for a single sensor should be consolidated to provide a single L2P data file<br />

SYS.0050<br />

SYS.0100<br />

for each sensor at 6 hourly intervals. These data should also be passed to the GHRSST-PP GDAC in near real time.<br />

37 URD-112 • A static archive of L2P data products that can (a) serve the needs of the GHRSST-PP reanalysis project and (b) be used<br />

as the starting point for any reprocessing effort if required. Because the data quality flagging for L2P data is experimental,<br />

it is important for the pilot project phase of GHRSST to be able to revisit the flagging criteria following quality analysis,<br />

SYS.0090<br />

SYS.2040<br />

ARC.0010<br />

which is facilitated by preserving a static archive.<br />

37 URD-113 • Level 4 analysed SSTfnd for Ultra High Resolution areas. The analysed product is the result of combining all available<br />

SYS.0080<br />

SST observations using an optimal interpolation (OI) scheme described in [RD-3].<br />

37 URD-114 • GHRSST-PP diagnostic data set granules as described in [RD-4] SYS.0070<br />

SYS.0071<br />

© 2004 SOC Page 110 of 193

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!