<strong>Medspiration</strong> MED-SOC-RS-001_1<br />

<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong> Issue F<br />

Page Table, fig. Reference ID Text from reference documents<br />

SR entry<br />

at the MMR as soon as the L2P data become available to the user community.<br />

65 WP-ID2.5.1 Format L2P MMR_FR metadata record<br />

65 WP2-238 A MMR_FR metadata record should be prepared for each L2P data file according to the specification provided in Appendix<br />

CTR.0530<br />

A6.2.<br />

65 WP-ID2.5.2 Register L2P MMR_FR metadata record with MMR system<br />

65 WP2-239 MMR_FR metadata records should be delivered to the MMR system as soon as possible after the L2P data set has been<br />

CTR.0580<br />

evaluated following the procedure described in Appendix A6.4.<br />

65 WP2-240 RDAC should aim to register MMR_FR records within 60 minutes of L2P data production in order that users are informed<br />

CTR.0580<br />

in a timely manner.<br />

65 WP2-241 It is recognised that, if the MMR_FR record is submitted by e-mail, delays in registration are beyond the control of the<br />

CTR.0110<br />

RDAC. At the 4 th GHRSST-PP Science Team workshop, it was proposed to enable MMR data records to be delivered to<br />

the MMR via ftp push from the RDAC to circumvent this problem.<br />

67 WP-ID3 The GHRSST-PP Matchup <strong>Data</strong> base (MDB) and derivation of Sensor Specific Error Statistics (SSES)<br />

Description:<br />

67 WP3-001 This WP describes the GHRSST-PP match up database system (MDB) and the MDB data records that should be<br />

NASR<br />

produced at each RDAC.<br />

67 WP3-002 The GDS requires that error estimates are assigned to every satellite SST measurement during the derivation of L2P data<br />

NASR<br />

products. As an in situ observation is not available for every SST measurement, Sensor Specific Error Statistics (SSES)<br />

are derived by a statistical analysis of MDB data records for a given sensor type and time period. SSES consist of a<br />

statistical mean bias and standard deviation (sd.) error estimate that is correlated to the mean L2P Proximity_confidence<br />

value for a given sensor. These values are then assigned to all L2P measurements that have the same<br />

Proximity_confidence value.<br />