Medspiration â System Requirements Document - Data User Element
Medspiration â System Requirements Document - Data User Element
Medspiration â System Requirements Document - Data User Element
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Medspiration</strong> MED-SOC-RS-001_1<br />
<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong> Issue F<br />
Page Table, fig. Reference ID Text from reference documents<br />
SR entry<br />
72 Rule<br />
WP3-059<br />
A minimum delay of 24 hours is to be expected when using data from operational in situ data centres due to the latency<br />
MDB.0030<br />
3.1.2e<br />
incurred by QC procedures<br />
72 Rule<br />
WP3-060 all MDB records are admissible irrespective of their timeliness for use by the GHRSST-PP reanalysis project MDB.0030<br />
3.1.2e<br />
72 Rule<br />
WP3-061<br />
Additional geophysical fields will be required to provide insight into any uncorrected perturbations to the SSTs which might<br />
MDB.0330<br />
3.1.2f<br />
result in systematic errors. All available in situ parameters should be included in the MDB record using the spare<br />
WP-ID3.1.2 Format of MDB record<br />
72 WP3-062 Each in situ SST matched to a near contemporaneous satellite SST will be formatted as an XML text file following the<br />
Format<br />
format described in Appendix A4.<br />
WP-ID3.1.3 Insert MDB record into the GHRSST-PP MDB system<br />
72 WP3-063 MDB data records should be sent to the GHRSST-PP MDB either as an e-mail message or via ftp put CTR.0580<br />
72 WP3-064 An error message will be returned to the data provider if the MDB record is incorrectly formatted. NASR<br />
WP-ID3.2: Derivation of SSES using MDB records<br />
78<br />
72-<br />
79-<br />
WP-ID3.3: Publish SSES on GHRSST-PP web site and inform RDAC/GDAC<br />
80<br />
WP-ID4: Generation of L4 Analysed data products (L4)<br />
Description<br />
81 WP4-001 The GDS will produce an analysed estimate of SSTfnd every 24 hours using analysis procedures that depend on L2P data<br />
SYS.0080<br />
products as input.<br />
© 2004 SOC Page 164 of 193