10. TESTING REQUIREMENTS<br />
SR.TST.SYS.0020/I In order to verify that each processing centre has implemented<br />
the GDS correctly a reference GDS data processor will be used to process a set of data<br />
products using a GDS test data set.<br />
SR.TST.SYS.0030/I<br />
generated.<br />
Error message indicating data set rejection shall be correctly<br />
SR.TST.SYS.0040/I<br />
Error message shall be delivered correctly to data provider.<br />
SR.TST.SYS.0050/I<br />
ERRLOG.<br />
Error messages shall be delivered correctly to the GHRSST-PP<br />
SR.TST.SYS.0060/I MMR_DSD records shall be prepared and registered correctly<br />
within the GHRSST-PP MMR system.<br />
SR.TST.SYS.0070/I<br />
L2 data files shall be correctly renamed.<br />
SR.TST.SYS.0080/I L2P output data products based on the GDS test input data set<br />
produced at each RDAC and GDAC should be identical to those produced by the GDS<br />
reference data processor.<br />
SR.TST.SYS.0090/I L2P measurement data shall be identical to the input SST data<br />
but with additional error and QC).<br />
SR.TST.SYS.0100/I<br />
manner.<br />
MMR_FR metadata records shall be submitted in a timely<br />