<strong>Medspiration</strong><br />
MED-SOC-RS-001_1<br />
<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong><br />
Issue F<br />
ambiguous since some sensor measurements may exist in different datasets with various<br />
resolutions (eg AVHRR).<br />
SR.MDB.0260/I A satellite pixel shall be colocated to only one in situ measurement from<br />
a single in situ data file. However, the scope of the colocation process for in situ data is<br />
limited to the data files : a satellite pixel may be colocated again with another in situ<br />
measurement delivered by CORIOLIS a few days or weeks later in another datafile<br />
There is no user requirements addressing this issue. Trying to avoid a satellite pixel<br />
being colocated with more than one in situ measurement would be complex to implement<br />
while addressing very rare cases. In particular it would almost imply building a MDB to<br />
filter out these cases which is not the aim of this system. If this issue is considered as<br />
critical, it should be adressed by the GDAC MDB when ingesting its records.<br />
SR.MDB.0270/I The targeted in situ measurement for the MDB records production are<br />
the SST1m data derived from drifting/moored buoy, ship and float (Argo) observations.<br />
For some sensors, the SST1m may not be accessible : it is thus proposed to catch the<br />
closest to the 1m depth in the limits of [-5m, 0m].<br />
It is stated in the GDS that the targeted in situ measurement for the MDB records<br />
production are the SST1m data derived from drifting/moored buoy and ship observations.<br />
After meeting with the CORIOLIS staff, it appears this may be too restrictive since very<br />
few ship observations are available beyond –5m. Relaxing this constraint allows to select<br />
more data and also to capture the floats data.<br />
3.3.3.3 Generating the MDB records<br />
SR.MDB.0310/I All L2P confidence data each pixel stored in a MDB record must<br />
accompany the extracted data.<br />
SR.MDB.0320/I For each L2P pixel matched to an in-situ measurement, a n x n array of<br />
L2P data shall be extracted centred on this pixel and provided within the related MDB<br />
record.<br />
SR.MDB.0330/I All in situ parameters available in addition to the SST measurement<br />
should be included in the MDB record.<br />
Upgrade of the MDB format (DTD) may be necessary. Additional parameters will be<br />
submitted to GHRSST-PP through ESA in order to keep consistency (variable names,<br />
units,…).<br />
© 2004 SOC Page 51 of 193