<strong>Medspiration</strong><br />

MED-SOC-RS-001_1<br />

<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong><br />

Issue F<br />

SR.SYS.0055/I For every L2P file that is generated, a L2P MMR_FR shall be created and<br />

registered under the appropriate MMR_DSD at the GHRSST-PP MMR system.<br />

SR.SYS.0060/I <strong>Medspiration</strong> shall be able to produce records for the GHRSST-PP<br />

match-up data base (MDB) of in situ measurements of SST coincident in space and time<br />

with L2P data for the European area.<br />

SR.SYS.0061/I The MDB products shall conform to the specification in [RD.1], [RD.2]<br />

and [RD.3] and detailed in 3.3.3<br />

SR.SYS.0070/I <strong>Medspiration</strong> shall be able to extract GHRSST-PP Diagnostic <strong>Data</strong> Set<br />

(DDS) granules [RD-4] for the European area.<br />

SR.SYS.0071/I The DDS shall conform to the specification in [RD.1], [RD.2] and [RD.3]<br />

and detailed in 3.4<br />

SR.SYS.0080/I <strong>Medspiration</strong> shall be capable of delivering L4 UHR products for the<br />

Mediterranean Sea in near-real time to selected operational users.<br />

SR.SYS.0081/I The <strong>Medspiration</strong> Mediterranean Sea product grid domain shall cover<br />

from 30N to 46N and from 6W to 36.5E at 2 km spatial resolution.<br />

SR.SYS.0082/I The system for generating L4 products shall be based on an optimal<br />

interpolation (OI) procedure that can be adapted to widely differencing conditions through<br />

the use of configuration files.<br />

SR.SYS.0083/I The L4 products shall conform to the specification in [RD.1], [RD.2] and<br />

[RD.3] and detailed in 3.3.2<br />

3.1.4 Archive and dissemination<br />

SR.SYS.0090/I <strong>Medspiration</strong> shall archive all L2P and L4 products in a static archive so<br />

that they can be available for any future reprocessing, and for the GHRSST-PP<br />

reanalysis project.<br />

SR.SYS.0100/I <strong>Medspiration</strong> shall provide a dissemination service for data products<br />

including the operational delivery of SST products to specific European operational users<br />

and to the GHRSST-PP GDAC.<br />

SR.SYS.0110/I <strong>Medspiration</strong> shall provide access to all its data products as an ftp push<br />

service for registered clients and ftp pull service for all users.<br />