Page Table, fig. Reference ID Text from reference documents<br />
51 WP2-092 The source of wind speed information must be specified in the L2P confidence data variable Wspd_source (defined in<br />
Table 2.1.4) and the difference in acquisition time between SST observation and wind speed measure must be specified in<br />
SR entry<br />
see next five<br />
rows<br />
the L2P confidence variable Wspd_Dtime_from_SST.<br />
51 The GDS specifies the following rules:<br />
51 Rule<br />
WP2-093<br />
Rule 2.1.4a: A 10m surface wind speed value should be assigned to each SST measurement pixel using the GDS L2P<br />
MRG.0130<br />
2.1.4a<br />
confidence data variable Wspd_value described in Table A1.2.2. As a general rule for the GDS v1.0, only simultaneous<br />
wind speed measurements should be used otherwise NWP analyses should be used. Future revisions of the GDS will<br />
most likely use near contemporaneous wind speed observations from other satellite instruments.<br />
51 Rule<br />
WP2-094<br />
Rule 2.1.4b: The source of data used to set the L2P confidence data variable Wspd should be indicated in the confidence<br />
Format<br />
2.1.4b<br />
variable Wspd_source as defined in Table 2.1.4.<br />
requirement<br />
51 Rule<br />
WP2-095<br />
Rule 2.1.4c: In the case of microwave SST measurements, the use of a simultaneous microwave 10m wind speed<br />
MRG.0150<br />
2.1.4c<br />
measurements obtained from the same instrument providing the SST measurement may be used.<br />
51 Rule<br />
WP2-096<br />
Rule 2.1.4d: In the absence of a simultaneous surface wind speed measurement, an NWP estimated 10m surface wind<br />
MRG.0160<br />
2.1.4d<br />
speed (See Appendix A3, Table A3.1.1) should be used to set the L2P confidence data variable Wspd_value.<br />
52 Rule<br />
WP2-097<br />
Rule 2.1.4e: The difference in time expressed in hours between the time of SST measurement and the time of wind speed<br />
MRG.0170<br />
2.1.4e<br />
measurement should be entered into the L2P confidence data variable Wspd_Dtime_from_SST. A value of 25 should be<br />
used to indicate unknown.<br />
52 Table<br />
2.1.4<br />
WP2-098 Code value for the source of the data used to assign the L2P confidence value Wspd_source Format<br />
requirement<br />
52 WP2-099 The following QC checks should be applied to all input wind speed data sets. The tests applied are simple tests designed<br />
QLC.0090<br />
to verify that wind speed data are within realistic limits.<br />
52 WP2-100 RDAC and GDAC may choose to implement more sophisticated QC procedures if deemed necessary.<br />