SR.EXP.L2P.0070/I The GDS reference processor system should be used to test all<br />

proposed upgrades so that the implications of the proposed changes may be evaluated<br />

prior to operational implementation.<br />

6.3 Diagnostic data set<br />

SR.EXP.DDS.0010/I The HR-DDS system shall be capable of ingesting new data<br />

sources with minimum effort.<br />

SR.EXP.DDS.0020/I The HR-DDS system shall be capable of producing data for any<br />

geographical region; however, total data volume may be limited by <strong>Medspiration</strong> to 10<br />

Gigabytes per month as necessary.<br />

SR.EXP.DDS.0030/I<br />

stream.<br />

The HR-DDS system not be dependant on any specific L2 data<br />

SR.EXP.DDS.0040/I The HR-DDS code shall not contain any ‘magic numbers’,<br />

editable configuration files shall be used.<br />

SR.EXP.DDS.0050/I No data source other than ATS_NR__2P shall be required to be<br />

mirrored on the AATSR mirroring service.<br />

SR.EXP.DDS.0060/I The Atlantic Extractor Process shall be capable of selecting data<br />

from additional rectangular regions within the limits already set, as defined by the<br />

GHRSST-PP Problem Resolution Board.#.<br />