SR.EXP.L2P.0070/I The GDS reference processor system should be used to test all<br />
proposed upgrades so that the implications of the proposed changes may be evaluated<br />
prior to operational implementation.<br />
6.3 Diagnostic data set<br />
SR.EXP.DDS.0010/I The HR-DDS system shall be capable of ingesting new data<br />
sources with minimum effort.<br />
SR.EXP.DDS.0020/I The HR-DDS system shall be capable of producing data for any<br />
geographical region; however, total data volume may be limited by <strong>Medspiration</strong> to 10<br />
Gigabytes per month as necessary.<br />
SR.EXP.DDS.0030/I<br />
stream.<br />
The HR-DDS system not be dependant on any specific L2 data<br />
SR.EXP.DDS.0040/I The HR-DDS code shall not contain any ‘magic numbers’,<br />
editable configuration files shall be used.<br />
SR.EXP.DDS.0050/I No data source other than ATS_NR__2P shall be required to be<br />
mirrored on the AATSR mirroring service.<br />
SR.EXP.DDS.0060/I The Atlantic Extractor Process shall be capable of selecting data<br />
from additional rectangular regions within the limits already set, as defined by the<br />
GHRSST-PP Problem Resolution Board.#.<br />