Medspiration â System Requirements Document - Data User Element
Medspiration â System Requirements Document - Data User Element
Medspiration â System Requirements Document - Data User Element
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Medspiration</strong><br />
<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong><br />
what is available at the cut-off time.<br />
MED-SOC-RS-001_1<br />
Issue F<br />
SR.INT.L4A.0040/I The UHR/L4 products shall be formatted as netcdf files with respect<br />
to the format provided in Annex 2 (“L4 product format”).<br />
4.1.6 Interfaces within the archiving system<br />
SR.INT.ARC.0510/I The archiving system shall use the existing offline mass storage<br />
subsystem existing at CERSAT to archive the historical data stored online. The interface<br />
of this subsystem is described in ‘<strong>Document</strong> de specification Logiciel de l’Atelier<br />
d’Archivage’ (ref : WCOL-DSL-A-03-CS). This interface may need to be updated to take<br />
into account <strong>Medspiration</strong> specificities.<br />
SR.INT.ARC.0520/I The online storage system of the archiving system shall be<br />
accessible for the offline mass storage system to restore historical data.<br />
SR.INT.ARC.0530/I The archiving system may use the existing referencing subsystem<br />
existing at CERSAT. The interface of this subsystem is described in ‘<strong>Document</strong> de<br />
specification Logiciel de l’Atelier Reception’ (ref : WCOL-DSL-R-02-CS). This interface<br />
may need to be updated to take into account <strong>Medspiration</strong> specificities.<br />
SR.INT.ARC.0540/I The online space storage shall be accessible by the backup system<br />
available at IFREMER which shall perform a nightly saving of every new or changed files.<br />
SR.INT.ARC.0550/I The online space storage shall be accessible for the backup system<br />
available at IFREMER to restore saved files if needed.<br />
4.1.7 Interfaces between HR-DDS production and dissemination systems<br />
SR.INT.DDS.0010/I The HR-DDS production system (SOC) shall be interfaced with the<br />
DODS server (in the IFREMER dissemination system) to subset and download the<br />
relevant L2P products for the computation of the related HR-DDS.<br />
SR.INT.DDS.0020/I The HR-DDS production system (SOC) shall be interfaced with<br />
the DODS server (in the IFREMER dissemination system) to subset and download the<br />
relevant L4UHR products for the computation of the related HR-DDS..<br />
SR.INT.DDS.0030/I There shall be an ftp interface between SOC and CMS for the<br />
movement of netCDF format AATSR data.<br />
SR.INT.DDS.0040/I<br />
There shall be an interface between SOC and GDAC for the<br />
© 2004 SOC Page 62 of 193