30.01.2015 Views

Medspiration – System Requirements Document - Data User Element

Medspiration – System Requirements Document - Data User Element

Medspiration – System Requirements Document - Data User Element

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Medspiration</strong> MED-SOC-RS-001_1<br />

<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong> Issue F<br />

Page Table, fig. Reference ID Text from reference documents<br />

SR entry<br />

53 Rule<br />

WP2-111<br />

Rule 2.1.5a: A 6 hourly integrated downwelling SSI measurement (e.g., derived from satellite measurements) should be<br />

MRG.0180<br />

2.1.5a<br />

assigned to each SST pixel value using the SSI_value L2P confidence data variable. The SSI measurement nearest in<br />

space and time before the input pixel SST value should be used.<br />

53 Rule<br />

WP2-112<br />

Rule 2.1.5b: If no SSI measurement is available, a 6 hourly integrated SSI value derived from an NWP system (See<br />

MRG.0190<br />

2.1.5b<br />

Appendix A3) nearest in space and time to the SST measurement should be used to set the value of SSI_value.<br />

53 Rule<br />

WP2-113<br />

Rule 2.1.5c: The source of data used to set the L2P confidence data variable SSI_value should be indicated in the<br />

MRG.0200<br />

2.1.5c<br />

confidence variable SSI_source as defined in Table 2.1.5.<br />

53 Rule<br />

WP2-114<br />

Rule 2.1.5e: The difference in time expressed in hours between the time of SST measurement and the mean time of SSI<br />

MRG.0210<br />

2.1.5e<br />

measurement/data validity should be entered into the L2P confidence data variable SSI_Dtime_from_SST. A value of 25<br />

should be used to indicate unknown.<br />

53 Table<br />

WP2-115 Code value for the source of the data used to assign the L2P confidence value SSI_source MRG.0200<br />

2.1.5<br />

53 WP2-116 The following QC checks should be applied to all input SSI data sets that are used at RDAC and GDAC. These tests are<br />

see following<br />

simple tests designed to verify that SSI data are within realistic limits. RDAC and GDAC may choose to implement more<br />

sophisticated QC procedures if deemed necessary.<br />

53 WP-ID2.1.5.1 Gross SSI limit check<br />

53 WP2-117 This test identifies data that fall outside of acceptable range of global SSI values. The GDS specifies the following rule: NASR<br />

53 Rule<br />

2.1.5.1<br />

WP2-118 Rule 2.1.5.1: A valid 6 hourly integrated SSI observation/forecast must lie within a SSI range of 0 < SSI <<br />

HighSSIValue. SSI values that fall outside this range should not be used within the GDS.<br />

QLC.0100<br />

53 WP2-119 The HighSSIValue value is set in the L2P configuration file maintained at the RDAC and GHRSST-PP International<br />

QLC.0120<br />

Project Office.<br />

53 P-ID2.1.6 L2P Aerosol Optical Depth (AOD) value assignment<br />

© 2004 SOC Page 143 of 193

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!