<strong>Medspiration</strong> MED-SOC-RS-001_1<br />
<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong> Issue F<br />
Page Table, fig. Reference ID Text from reference documents<br />
SR entry<br />
67 WP3-003 In addition, The MDB system also provides a resource that can be used to validate GHRSST-PP data products. NASR<br />
67 WP3-004 In the case of microwave SST, the derivation of SSES also requires that error components are assigned to each pixel<br />
NASR<br />
based on static look-up-tables of mean error due to sidelobe contamination, proximity to rain and wind speed. These<br />
tables will be provided by Remote Sensing <strong>System</strong>s (RSS) for the TMI and AMSR-E (and in the future, Windsat)<br />
microwave instruments.<br />
67 WP3-005 The main source of in situ observations used in this system will be those available from the GTS supplied through<br />
NASR<br />
international in situ data centres (e.g., MED, CORIOLIS, FNMOC) at which QC procedures are used to filter out poor<br />
quality data.<br />
67 WP3-006 These data centres only provide in situ observations in a delayed mode (typically 24-72 hours, although delays may be<br />
MDB.0010<br />
longer than this) and therefore RDAC and GDAC can only provide MDB records in a delayed mode.<br />
67 WP3-007 RDAC are expected to arrange access to regional in situ data sources that are not available via the GTS system but can<br />
MDB.0120<br />
be included in the MDB system.<br />
67 WP3-008 The GHRSST-PP reanalysis project will be able to make use of other in situ observations that are unavailable in a NRT<br />
NASR<br />
mode.<br />
inputs<br />
68 WP3-009 • L2P data files MDB.0040<br />
68 WP3-010 • In situ ocean-atmosphere measurements from buoys, drifters and ships MDB.0020<br />
68 WP3-011 • SSES configuration file NASR<br />
68 WP3-012 • Static Look-up-Table (LUT) of microwave SST sidelobe contamination error NASR<br />
68 WP3-013 • Static LUT of microwave SST rain contamination errors NASR<br />
68 WP3-014 • Static LUT of microwave SST wind speed errors NASR<br />
outputs<br />
© 2004 SOC Page 159 of 193