<strong>Medspiration</strong> MED-SOC-RS-001_1<br />

<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong> Issue F<br />

Page Table, fig. Reference ID Text from reference documents<br />

SR entry<br />

products to European users and the GHRSST-PP GDAC.<br />

7 sow-060 It must be able to ingest, process and disseminate large volumes of satellite and in situ data in near real time. SYS.0015<br />

DIS.0020<br />

DIS.0030<br />

7 sow-061 It must also be capable of real time ftp push and pull high-volume data delivery services [AP-1]. DIS.0110<br />

DIS.0120<br />

7 sow-062 The scope of the <strong>Medspiration</strong> system should consider the data streams and data volumes outlined in [AP-2], Table 4.2.1. SYS.0030<br />

7 sow-063 Figure 1.5.1 shows a functional decomposition diagram of the major data processing activities within the <strong>Medspiration</strong><br />

SRD Fig 2.4<br />

9 1.7 Prerequisites<br />

project together with associated input and output products.<br />

9 The following key issues shall be taken into consideration by the Contractor when executing the work:<br />

9 sow-064 • The GHRSST-PP and <strong>Medspiration</strong> is focussed on the provision of an operational near real time generation of SST data<br />

SYS.0015<br />

products.<br />

9 sow-065 Timeliness of data production, dissemination SYS.0015<br />

9 sow-066 and reliability of the <strong>Medspiration</strong> software system are critical to the success of the service. DES.SYS.0030<br />

CTR.0110<br />

9 sow-067 • Where possible the <strong>Medspiration</strong> shall rely on the use of configuration files [lookup tables] and implement configurable<br />

code [AP-4, page 13] that allows the processing model to be tuned (e.g., based on experience decorrelation length scales<br />

and various input parameters are expected to evolve) without the need to modify the <strong>Medspiration</strong> system software.<br />

DES.SYS.0040<br />

EXP.DDS.0010<br />

EXP.DDS.0020<br />

EXP.DDS.0030<br />

EXP.DDS.0040<br />

9 sow-068 • The optimal interpolation scheme used to derive L4 SSTfnd data products is expected to evolve as more experience is SYS.0082<br />