<strong>Medspiration</strong> MED-SOC-RS-001_1<br />

<strong>System</strong> <strong>Requirements</strong> <strong>Document</strong> Issue F<br />

Page Table, fig. Reference ID Text from reference documents<br />

58 WP2-170 Note that the actual values for IPCVThres1-3 and IPCV_D1 and IPCV_D2 are expected to vary for each sensor (Brisson<br />

SR entry<br />

CFD.0370<br />

et al., 2001) and the exact value of these parameters is a subject of on-going research and development within the<br />

GHRSST-PP. IPCVThres1-3, IPCV_D1 and IPCV_D2 values will be maintained by the GHRSST-PP International Project<br />

Office and stored in the L2P configuration file that is specific to each RDAC or GDAC.<br />

58 WP2-171 The derivation of these values will initially use best estimates until a sufficiently large population of data within the<br />

CFD-0320<br />

GHRSST-PP MDB is available (e.g., those suggested by Brisson et al. (2001).<br />

58 WP2-172 The filename of this configuration file should be written into each L2P file using the optional global netCDF attribute<br />

“References” as described in Appendix A1.2.1.<br />

Format<br />

requirement<br />

58 WP2-173 It is expected that the methodology used to derive IPCV may be modified in the GDSv2. EXP.L2P.0030<br />

59 WP-ID2.2.1.5 Assign Sensor Specific Error Statistic<br />

59 WP2-174 This processing step is used to assign the L2P confidence data record variable bias and sd defined in Table A1.2.2 in<br />

Appendix A1.<br />

L2P.6010<br />

L2P.6020<br />

59 The GDS specifies the following rules:<br />

59 Rule<br />

WP2-175<br />

Rule 2.2.1.5a: If pixel bias error and sd error statistics are provided by a data provider, these values may be assigned to<br />

L2P.6010<br />

2.2.1.5a<br />

the L2P bias and sd variables respectively. In this case, the L2_native_bias and L2_native_sd flags of the<br />

corresponding L2P confidence data record should also be set as these error estimates are independent of GHRSST-PP<br />

methods.<br />

59 WP2-176 If native bias and sd error values are not available or an RDAC chooses to ignore the error statistics provided by a data<br />

provider, these must be assigned based on the L2P Proximity_Confidence variable using sensor specific error statistics<br />

L2P.6020<br />

CFD.0020<br />

(SSES) as described in WP-ID3. In this case the L2_native_bias and L2_native_sd. flags of the corresponding L2P<br />

confidence data record should be set to zero.<br />

59 The GDS specifies the following rule:<br />

© 2004 SOC Page 150 of 193