MAGUIRE PRODUCTS, INC.<br />
Selecting the Correct Model<br />
Controllers are programmed to control all sizes of Weigh Scale Blenders.<br />
The MODEL number that your unit is set for will be displayed during the start up sequence<br />
every time power is turned on.<br />
The possible models are:<br />
Blender Model Blender Display Code Batch Weight (Grams) Weigh Bin Dimensions Load Cell Rating<br />
MB MB 400 5” x 5” x 5” High 1 @ 3Kg<br />
140 / 140R 140 / 14R 1000 10” x 6” x 6” High 1 @ 3Kg<br />
220 220 2000 10” x 10” x 7” High 2 @ 3 Kg<br />
240 / 240R / 260 240/24R 2000 10” x 10” x 7” High 2 @ 3 Kg<br />
420 420 4000 10” x 10” x 10” High 2 @ 10 Kg<br />
440 / 440R / 460 440/44R 4000 10” x 10” x 10” High 2 @ 10 Kg<br />
940 / 960 940 9000 16” x 16” x 12” High 2 @ 10 Kg<br />
1840 / 1860 1840 18000 16” x 16” x 17” High 2 @ 20 Kg<br />
“R” Models have 2 removable hoppers<br />
The addition of feeders will change the last digit of the model number.<br />
This digit can be ignored for selecting the correct Model.<br />
400, 1000 and 2000 gram systems with 3 Kg load cells; weights are displayed in tenths of<br />
grams (xxxx.x).<br />
4000, 9000, and 18000 gram systems with 10 or 20 Kg load cells; weights are displayed in full<br />
grams (xxxxx).<br />
If your unit is NOT set correctly to match the hardware you have, you must change it. To do so:<br />
Turn power on. From the NORMAL mode:<br />
Model Setup Keypad Sequence:<br />
Press<br />
Display will say: (PASSWORD)<br />
Press Display will say: (MODEL 220)<br />
Or<br />
Whatever model it is currently set for.<br />
Press<br />
Press<br />
To scroll through all model sizes.<br />
When the model you want is displayed, then:<br />
Wait a few seconds.<br />
Controller will reset and restart as the system you have selected.<br />
When switching models, all parameter table information is lost and the new "default" information for this model is<br />
loaded from ROM.<br />
If you should be in any doubt as to which is the correct model you should select please stop and contact your local<br />
<strong>Maguire</strong> representative who will inform you by return.<br />
Edition: March 24, 2008 20