MAGUIRE PRODUCTS, INC.<br />

Special Instructions for Selected Models<br />

This section relates SPECIAL information about a few selected models.<br />

MICRO PULSE<br />

Micro Pulse valves are available on models:<br />

WSB MB<br />

with optional VERTICAL VALVE MICRO PULSE valves.<br />

WSB 122 / WSB 140m2 with optional SLIDE GATE MICRO PULSE valves.<br />

WSB 131 / WSB 140m1 with optional SLIDE GATE MICRO PULSE valves.<br />

WSB 140Rm1 / WSB 140Rm2 with optional VERTICAL VALVE MICRO PULSE valves.<br />

WSB 240Rm1 / WSB 240Rm2 with optional VERTICAL VALVE MICRO PULSE valves.<br />

WSB 440Rm1 / WSB 440Rm2 with optional VERTICAL VALVE MICRO PULSE valves.<br />

These models may use our "MICRO PULSE" metering system for Color and Additive components.<br />

PULSED OUTPUT parameters control the on/off timing, or pulsing, of the valves. The controlling<br />

parameters are the "_PO" component parameters.<br />

When set to 00000, normal slide gate operation occurs. When set to a value, such as 03030, power will<br />

pulse ON then OFF, at 30 interrupt time intervals each way. This ON/OFF cycling will repeat for the<br />

entire dispense time.<br />

When using a MICRO PULSE valve, you must set the related _PO parameter to 03030.<br />

If overall blender throughput is too low, you may increase the metering rate of each Micro Pulse device<br />

by adjusting the cylinder airflow control valves for higher flow rate. This causes more rapid movement<br />

of the cylinder, ejecting more pellets per pulse. The drawback is noisy operation.<br />

We recommend air flow be adjusted for quiet operation, but assuring full valve movement per on/off<br />

cycle. We have already done this. No further adjustment should be necessary.<br />

The approximate correct airflow adjustments are:<br />

At nose of cylinder, 1.5 full turns out from full closed.<br />

At rear of cylinder, 2.5 full turns out from full closed.<br />

MICRO BLENDER slant valves, adjust by sound.<br />

On fixed hoppers with horizontal micro pulse valves, CLEAN OUT of the hopper can be accomplished<br />

by opening the "clean out" port provided under the valve. Turn to one side to allow material to drain.<br />

MICRO PULSE - ACCURACY<br />

All MICRO PULSE valves are more accurate if the associated PT parameter is set to 00090. Read PT<br />

parameter in the PARAMETER section.<br />

PROCEED TO: NORMAL OPERATION NEXT PAGE<br />

Edition: March 24, 2008 28