<strong>WEIGH</strong> <strong>SCALE</strong> <strong>BLENDER®</strong><br />
MAGUIRE PRODUCTS, INC.<br />
Materials Rate Calibration<br />
YOU DO NOT HAVE TO DO THIS.<br />
Software is set to expect STANDARD hardware. If a device meters at a much lower feed rate then expected, the software will<br />
take 10 to 20 cycles to fully adjust. During this time cycles will take longer.<br />
An example of this is a system using a 1/2" auger instead of 1".<br />
If you don't mind letting the system SELF ADJUST, or your hardware is STANDARD, then:<br />
PROCEED TO: ENTERING SETTINGS NEXT PAGE<br />
To perform a RATE CALIBRATION:<br />
Have the HOPPER LOADED with enough material to run for several cycles without running out.<br />
Have the "OFF AT END OF CYCLE" and "PAUSE" switches DOWN.<br />
Material Calibration Keypad Sequence:<br />
Press<br />
Display will say: (PASSWORD)<br />
Press Display will say: (P x)<br />
If you are calibrating an auger feeder, operate it briefly to ensure it is fully primed. To do so:<br />
Press<br />
Press<br />
Press<br />
or<br />
Display will say: (OPERATE)<br />
Run until Auger Feeder is dispensing<br />
This will empty the Weigh Bin<br />
Now you can CALIBRATE the material. To do so:<br />
Press<br />
Press<br />
Display will say: (CALIBRATE)<br />
Component #5 will calibrate itself.<br />
Repeat this two key calibration routine for EACH material that you wish to calibrate. Only components that have a TYPE<br />
selected (not "OFF") will operate.<br />
Each time a dispense will occur, followed by weighing, followed by a dump to empty the weigh bin.<br />
Press Display will say: ( x)<br />
YOU ARE NOW READY FOR ACCURATE PRODUCTION BLENDING.<br />
PROCEED TO: ENTERING SETTINGS NEXT PAGE<br />
Edition: March 24, 2008 26