Sometimes throughput is slow enough that each new batch buries the mix blade for a<br />
while. When this happens the material on top does not mix well. To reduce this, you can<br />
delay the start of a new batch by increasing the DLY parameter. The new batch is<br />
delayed and mix chamber level has time to fall before the next batch is added.<br />
PRC<br />
No change required<br />
PRC is the maximum allowable PERCENT rate change per cycle. If a large dispense<br />
error occurs, flow rate corrections do not exceed this percent number. This prevents large<br />
swings in timing of dispenses and provides for stable dispense rates under difficult<br />
conditions. For example, when dispense quantities are very small (one or two grams),<br />
overfeeding by several grams is a distinct possibility. This type of error represents a very<br />
large percentage error to the controller.<br />
However, a large correction would not be appropriate but, instead, would cause a<br />
"hunting" of dispense time that would result in further large errors. This parameter<br />
prevents this.<br />
STL<br />
No change required<br />
STL is the TIME period allowed to pass after a dispense has occurred, but before a<br />
weight reading is taken. This settle time allows falling pellets to reach the bin and also<br />
prevents their impact with the bin from adding to the weight reading.<br />
LCL<br />
LCH<br />
LCF<br />
LCZ<br />
DS1<br />
DS2<br />
DS3<br />
DO NOT CHANGE THESE<br />
These four parameters are set to match the characteristics of the type of load cells used<br />
in your system. DO NOT ALTER THEM. LCL and LCH are the acceptable LOW and<br />
HIGH limits of load cell output expressed as raw signal counts per gram of weight. LCF is<br />
the lowest acceptable FULL scale load cell output expressed as raw signal counts per<br />
second. LCZ is the highest acceptable ZERO scale output. LCF and LCZ values are<br />
multiplied by 256 before being used by the software.<br />
Function in Dispenser mode only.<br />
Override top, middle and bottom thumbwheel switch settings.<br />
When the system is operating as a dispense system, (FUL 00001), the dispense weight is<br />
retrieved from the top thumbwheel switch or from the recipe file if the middle thumbwheel<br />
is set to a recipe number.<br />
If either DS1, DS2 or DS3 is set to any value greater then zero:<br />
Substitute DS1 for the TOP switch settings,<br />
Substitute DS2 for the MIDDLE switch settings, and<br />
Substitute DS3 for the BOTTOM switch settings<br />
These three parameters allow MLAN to download the dispense weight amount or recipe<br />
number. They also allow entry of a "locked in" amount or recipe.<br />
If BOTH DS1, DS2 and DS3 are set to 00000, then nothing changes.<br />
The middle thumbwheel switch setting for a recipe will override the top switch setting.<br />
When loading a weight into DS1, load 00000 into DS2 to be sure DS1 will control.<br />