<strong>WEIGH</strong> <strong>SCALE</strong> <strong>BLENDER®</strong><br />
MAGUIRE PRODUCTS, INC.<br />
• Vibration is causing frequent "bailouts" causing large swings in rate adjustment.<br />
Increase the BER parameter.<br />
7. The THUMBWHEEL SWITCHES do not seem to be controlling output. One or more<br />
LEDs (bottom row) are on all the time.<br />
• Someone has LOCKED IN a setting using the keypad. See KEYPAD, PROGRAM<br />
MODE, SETTING.<br />
• The _SE parameter is LIMITING the thumbwheel switch setting. See KEYPAD,<br />
PROGRAM MODE, and PARAMETERS, _SE.<br />
8. Occasionally, the system gets STUCK doing retries of a component but the retry<br />
time is so short that nothing gets dispensed.<br />
• The LAG TIME parameter is set for too short a time. See KEYPAD, TIME, and<br />
PARAMETER, _LA.<br />
• A valve is sticking closed. Check for free operation when air pressure is removed.<br />
9. The system USED TO WORK but now it does unexplainable things.<br />
• Static or a voltage surge has altered RAM memory. Do a CLEAR or CLEAR ALL.<br />
See "CLEAR" RESTART or "CLEAR ALL" RESTART. Then do a LOAD CELL<br />
CALIBRATION, and RATE CALIBRATION for ALL materials.<br />
10. The Display reads 3100.0 even with the bin empty. This is the upper limit load cell<br />
readout.<br />
• The Load Cells are not plugged in and the circuitry has drifted to the top limit.<br />
• The Load Cells have been overloaded way beyond their limit and are now<br />
permanently deflected.<br />
11. Dispenses from a slide gate are not as consistent as they should be.<br />
• The slide gate is sticking slightly. With the hopper empty, move the slide manually to<br />
see that it moves freely. Press up or down on the air cylinder to adjust for proper<br />
alignment.<br />
• The material does not flow very well. A bridge breaker adaptor may be required.<br />
12. Load Cell weight readings are not holding steady. They vary as much as 100<br />
grams from second to second.<br />
• This is static and improper grounding. See WIRING CONSIDERATIONS<br />
• If readings drift slowly in one direction, requiring frequent recalibration, a component<br />
on the circuit board is most likely faulty. Call us.<br />
• If TARE weights are not steady, something may be physically interfering with free<br />
movement of the cells.<br />
13. At the end of each cycle the MIX MOTOR runs for a fraction of a second only.<br />
Edition: March 24, 2008 89