<strong>WEIGH</strong> <strong>SCALE</strong> <strong>BLENDER®</strong><br />

MAGUIRE PRODUCTS, INC.<br />

• Vibration is causing frequent "bailouts" causing large swings in rate adjustment.<br />

Increase the BER parameter.<br />

7. The THUMBWHEEL SWITCHES do not seem to be controlling output. One or more<br />

LEDs (bottom row) are on all the time.<br />

• Someone has LOCKED IN a setting using the keypad. See KEYPAD, PROGRAM<br />

MODE, SETTING.<br />

• The _SE parameter is LIMITING the thumbwheel switch setting. See KEYPAD,<br />

PROGRAM MODE, and PARAMETERS, _SE.<br />

8. Occasionally, the system gets STUCK doing retries of a component but the retry<br />

time is so short that nothing gets dispensed.<br />

• The LAG TIME parameter is set for too short a time. See KEYPAD, TIME, and<br />

PARAMETER, _LA.<br />

• A valve is sticking closed. Check for free operation when air pressure is removed.<br />

9. The system USED TO WORK but now it does unexplainable things.<br />

• Static or a voltage surge has altered RAM memory. Do a CLEAR or CLEAR ALL.<br />

See "CLEAR" RESTART or "CLEAR ALL" RESTART. Then do a LOAD CELL<br />

CALIBRATION, and RATE CALIBRATION for ALL materials.<br />

10. The Display reads 3100.0 even with the bin empty. This is the upper limit load cell<br />

readout.<br />

• The Load Cells are not plugged in and the circuitry has drifted to the top limit.<br />

• The Load Cells have been overloaded way beyond their limit and are now<br />

permanently deflected.<br />

11. Dispenses from a slide gate are not as consistent as they should be.<br />

• The slide gate is sticking slightly. With the hopper empty, move the slide manually to<br />

see that it moves freely. Press up or down on the air cylinder to adjust for proper<br />

alignment.<br />

• The material does not flow very well. A bridge breaker adaptor may be required.<br />

12. Load Cell weight readings are not holding steady. They vary as much as 100<br />

grams from second to second.<br />

• This is static and improper grounding. See WIRING CONSIDERATIONS<br />

• If readings drift slowly in one direction, requiring frequent recalibration, a component<br />

on the circuit board is most likely faulty. Call us.<br />

• If TARE weights are not steady, something may be physically interfering with free<br />

movement of the cells.<br />

13. At the end of each cycle the MIX MOTOR runs for a fraction of a second only.<br />

Edition: March 24, 2008 89