WEIGH SCALE BLENDER® - Maguire Products
WEIGH SCALE BLENDER® - Maguire Products
WEIGH SCALE BLENDER® - Maguire Products
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>WEIGH</strong> <strong>SCALE</strong> <strong>BLENDER®</strong><br />
MAGUIRE PRODUCTS, INC.<br />
Clear All - Keypad Sequence:<br />
Switch<br />
Hold<br />
Switch<br />
Release<br />
Power Off to the Controller<br />
Hold these keys down simultaneously<br />
Power on to the Controller<br />
Release the keys<br />
When done correctly the display will say (CLEARALL).<br />
If you do not see ( CLEARALL ) on the display, do it again.<br />
LOAD CELL calibration WILL be lost. You will have to follow the Load Cell calibration procedure given in this manual.<br />
Since parameter table information is lost, you will want to reenter parameters that were previously modified. See BRIEF<br />
EXPLANATION of PARAMETERS for a quick review of which ones might have been changed.<br />
Be certain that your unit displays the proper MODEL number when you turn on power. If not, see SELECTING CORRECT<br />
MODEL.<br />
CORE DUMP<br />
During production or between cycles, the controller can be forced to print a CORE DUMP of Memory. This is helpful to us<br />
when elusive problems are occurring related to non-predictable environmental problems. If you are having reoccurring<br />
problems, we may ask you to use this routine during production to help us diagnose the problem.<br />
To obtain a MEMORY CORE DUMP, have a printer connected. Press three keys at the same time; the PARA, FULL, and<br />
ALRM keys; bottom row: left center and right.<br />
Edition: March 24, 2008 95