WEIGH SCALE BLENDER® - Maguire Products
WEIGH SCALE BLENDER® - Maguire Products
WEIGH SCALE BLENDER® - Maguire Products
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>WEIGH</strong> <strong>SCALE</strong> <strong>BLENDER®</strong><br />
MAGUIRE PRODUCTS, INC.<br />
Normal Operating Sequence - Each Cycle<br />
As the sensor is uncovered, the cycle begins. The target weight of a complete batch is 18000, 9000, 4000, 2000, 1000, or 400<br />
grams.<br />
REGRINDS are dispensed first, in their order of size, largest dispense first. After all the Regrind dispenses, the space<br />
remaining in the weigh bin is determined.<br />
NATURALS are dispensed second, in their order of size, each at the correct ratio to the others. These dispenses are<br />
calculated to fill the bin leaving just enough space for the Additive dispenses. After all Natural dispense are complete the<br />
exact weight of all of the NATURALS is determined and, based on this actual dispense weight, the Additive dispenses are now<br />
calculated.<br />
ADDITIVES are dispensed last. These dispenses are calculated as a percentage of all the NATURAL components only.<br />
If any dispense fails to reach the requested weight, the process does NOT CONTINUE. The ALARM Strobe light flashes, the<br />
Beeper sounds, and the system continues to retry the dispense until the problem is remedied.<br />
The total batch is then dropped into the mixing chamber for blending before entering the throat of the process machine.<br />
Special Features<br />
To use one of these SPECIAL FEATURES, read about it first. The KEYSTROKE sequence required is given at the end of this<br />
section.<br />
Function: Key: Description:<br />
TAG<br />
RECIPES<br />
FAST<br />
BATCH<br />
To TAG all material usage data with Work Order or Employee numbers for better tracking of<br />
material used, read: KEYPAD, TAG key, and set 2nd digit in the FLG parameter to 1.<br />
To store RECIPES using the RECIPE storage feature, read: KEYPAD, RECIPE key, and set<br />
3rd digit in the FLG parameter to 1.<br />
To increase throughput, using the FAST key, read: KEYPAD, FAST key, and set 4th digit in<br />
the FLG parameter to 1.<br />
To blend a preset BATCH amount of material and then stop, read: KEYPAD, BATCH key, and<br />
set 5th digit in the FLG parameter to 1.<br />
BATCH, RECIPE, FAST, and TAG keys REQUIRE that you read: PARAMETERS, FLG parameter.<br />
SETTINGS<br />
MIXING<br />
SETTINGS<br />
PASSWORDS<br />
ACCURACY<br />
DATA<br />
SOFTWARE<br />
To use a lower percentage then 00.1 percent, read: PARAMETERS, _XT parameter.<br />
To change the MIXER RUN TIME, read: PARAMETERS, MIX Parameter.<br />
To place UPPER LIMITS on settings, read: PARAMETERS, _SE Parameter.<br />
To LOCK OUT others from changing the settings, read: PARAMETERS, (*78) - Changing the<br />
Password.<br />
To VERIFY ACCURACY of the entire system, read: PRINTER OUTPUT and<br />
TROUBLESHOOTING sections.<br />
To TRACK MATERIAL USAGE, read: KEYPAD, VIEW DATA, and PARAMETERS, PRT<br />
Parameter.<br />
To configure TWELVE software to look and act like FOUR software, See: KEYPAD, STAR<br />
FUNCTIONS (*04) - Configuration to FOUR software.<br />
READ the rest of the manual at your leisure to learn more about how your <strong>WEIGH</strong> <strong>SCALE</strong> BLENDER works and what else the<br />
blender can do.<br />
Edition: March 24, 2008 30