(4) CODE128 code selection check<br />

Check if selection of (CODE A), (CODE B), or (CODE C) of CODE128 has been<br />

set correctly. If an error is found, the bar code will not be drawn.<br />

[Conditions causing an error]<br />

No start code is designated.<br />

A small letter (including { , | , } , ~, _ ) is found in (CODE A).<br />

A control character is found in (CODE B).<br />

Any data other than the numerals, (FNC1), (CODE A), and (CODE B) is found<br />

in (CODE C).<br />

There are two or more consecutive (SHIFT) characters.<br />

The number in (CODE C) is an odd number of digits.<br />

(SHIFT) is followed by (CODE A), (CODE B) or (CODE C).<br />

(5) Kanji code selection<br />

• In the case of Data Matrix, PDF417, and QR code, Kanji codes can be printed.<br />

Shift JIS, JIS hexadecimal, JIS 8 codes can be mixed.<br />

(6) Link field data string<br />

• After the link field No. is designated in the Format Command, data strings are<br />

linked using the Link Field Data Command to draw an image.<br />

• Up to 2000 digits of data strings of Data Matrix and PDF417 can be linked.<br />

For other bar codes, up to 126 digits can be linked. (The value varies<br />

according to the type of bar code.)<br />

When the number of digits exceeds the maximum value, excess data will be<br />

discarded.<br />

• Up to 99 data strings can be linked.<br />

• Up to 2048 bytes can be used as the command length ([ESC] to [NUL]) of the<br />

Link Field Data Command.<br />

• When the data string is omitted in the Link Field Data Command, the following<br />

process is performed:<br />

No process will be performed for the field which contains no print data due to<br />

the omission.<br />

When the field partially loses print data due to the omission, the only<br />

remaining data will be processed as print data.<br />

• The Link Field Data Command can be used for the bit map font fields, outline<br />

font fields, and bar code fields.<br />

(The same result is obtained when any of the “RC,” “RV”, or “RB” command<br />

code is designated.)<br />