(5) Head Open Error<br />

If the head open sensor detects the open state in 5 mm continuously, an error will result.<br />

If the head open sensor detects the open state when an issue, a feed, or an ejection is<br />

attempted in a printer stop state, an error will result.<br />

If the head-up sensor detects the head-up state in 5 mm continuously, an error will result.<br />

If the head-up sensor detects the head-up state when an issue, a feed, or an ejection is<br />

attempted in a printer stop state, an error will result.<br />

However, the feeding by the [FEED] key on the printer and the issuing and feeding by the<br />

expansion I/O are not included.<br />

(6) Thermal Head Error<br />

A broken dot error has occurred in the thermal head.<br />

An error has occurred in the thermal head driver.<br />

(7) Thermal Head Excessive Temperature<br />

When the open-air temperature detection thermistor detects an excessively high temperature<br />

(61 °C or more), an error will result.<br />

When the thermal head temperature detection thermistor detects an excessively high<br />

temperature (80 °C or more), an error will result.<br />

When the heat sink sensor detects an excessively high temperature (91 °C or more), an error<br />

will result.<br />

(8) Ribbon Error<br />

When the ribbon rewind motor sensor and ribbon back tension motor sensor do not perform<br />

detection if twice the prescribed time has passed, an error will result.<br />

• An abnormal condition has occurred in the sensor for determining the torque for the ribbon<br />

motor.<br />

• A ribbon jam has occurred.<br />

• The ribbon has run out.<br />

• The ribbon has not been installed.<br />

(9) Rewinder Overflow<br />

If the rewinder overflow sensor detects the overflow state in 5 mm continuously when the strip<br />

function or the built-in rewinder is specified, an error will result.<br />

If the overflow sensor detects an overflow state when an issue, a feed, or an ejection is<br />

attempted in a printer stop state after the strip function or the built-in rewinder is specified, an<br />

error will result.<br />

* At the moment an error occurs, the printer shows the error message, makes a status response,<br />

and then stops. Only the Status Request Command and the Reset Command can be<br />

processed. Other commands are not processed. Restoration using the [RESTART] key is<br />

possible except in the case of a thermal head excessive temperature error. (The printer<br />

resumes printing a label at which the error had occurred.)<br />