28.06.2015 Views

B-SX4T Series, B-SX5T Series External ... - Toshiba Tec Italia

B-SX4T Series, B-SX5T Series External ... - Toshiba Tec Italia

B-SX4T Series, B-SX5T Series External ... - Toshiba Tec Italia

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

(13) Link field No.<br />

The link field No. can be programmed by designating it after the symbol “;.” After the link<br />

field No. is designated using the Format Command, the data strings are linked by the Link<br />

Field Data Command to draw an image.<br />

Up to 20 fields can be linked.<br />

The following shows an example of linked fields on the two continuous labels.<br />

[Format Command]<br />

[ESC] PV01; ........................ ; 01 [LF] [NUL]<br />

[ESC] PV02; ........................ ; 03 [LF] [NUL]<br />

[ESC] PV03; ........................ ; 04 [LF] [NUL]<br />

[ESC] XB01;................... ; 03, 04 [LF] [NUL]<br />

[ESC] PV04; ........................ ; 02 [LF] [NUL]<br />

[ESC] PV05; ........................ ; 03 [LF] [NUL]<br />

[ESC] PV06; ........................ ; 04 [LF] [NUL]<br />

[ESC] XB02;................... ; 03, 04 [LF] [NUL]<br />

: Link field No. 1 is designated.<br />

: Link field No. 3 is designated.<br />

: Link field No. 4 is designated.<br />

: Link fields No. 3 and No. 4 are<br />

designated.<br />

: Link field No. 2 is designated.<br />

: Link field No. 3 is designated.<br />

: Link field No. 4 is designated.<br />

: Link fields No. 3 and No. 4 are<br />

designated.<br />

[Data Command]<br />

[ESC] RV; A [LF] B [LF] ABCD [LF] 001 [LF] [NUL]<br />

Designating the link field No.<br />

Link field No. 4<br />

Link field No. 3<br />

Link field No. 2<br />

Link field No. 1<br />

A<br />

B<br />

ABC<br />

D<br />

*ABCD001*<br />

ABCD<br />

001<br />

*ABCD001*<br />

Notes (1) The check digit attachment, increment/decrement, and zero suppress processes<br />

are performed according to the following priority. If any of the conditions are<br />

improper, no drawing will take place.<br />

For example, the zero(s) is replaced by a space(s) as a result of zero<br />

suppression but the modulus 10 designated to be attached cannot be calculated.<br />

Increment/decrement > zero suppression > attachment of check digit<br />

(2) Up to 32 fields for which incrementing/decrementing has been designated can be<br />

drawn. If the total bit map font, outline font, and bar code increment/decrement<br />

fields exceeds 32, drawing will take place without incrementing/decrementing any<br />

excessive field. The field to be incremented or decremented is incremented or<br />

decremented until the Image Buffer Clear Command ([ESC] C) is transmitted.<br />

- 89 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!