6.5.2 RFID TAG READ COMMAND [ESC] WF<br />

Function<br />

Format<br />

Term<br />

Reads the data stored on the RFID tag which is positioned just above the antenna.<br />

[ESC] WF (;) (Naaaa) (,Abbb) (,Tcc) (,Id) (,Jeeeeeeee) (,Xfgggggggg…) [LF] [NUL]<br />

Naaaa: Number of bytes to be read (Omissible)<br />

0001 to 4096<br />

When omitted, the number of bytes specified for the tag type being used will<br />

be designated.<br />

Abbb: Address of data to be read (Omissible)<br />

000 to 999<br />

The address where reading the RFID tag is started is specified.<br />

This parameter is effective for the ISO18000-6B tag only.<br />

When omitted, the value will be set to 18.<br />

Tcc:<br />

Id:<br />

Type of tag (Omissible)<br />

00: None<br />

11: I-Code<br />

12: Tag-it<br />

13: C220<br />

14: ISO15693<br />

15: C210<br />

16: C240<br />

17: C320<br />

21: EPC Class 0<br />

22: EPC Class 1<br />

23: ISO18000-6B<br />

24: EPC Class 1 Generation 2<br />

Designates the type of RFID tag from which data is to be read.<br />

When omitted, the tag type set in system mode will be designated.<br />

In accordance with the tag type designated by this setting, the tag type set in<br />

system mode changes.<br />

When “00: NONE” is designated, the backed up tag type will be set, and the<br />

system mode setting will not be changed.<br />

RFID read mode (Omissible)<br />

1: Only user data is read.<br />

2: Only tag ID is read.<br />

3: Both tag ID and user data are read.<br />

When omitted, only user data will be read.<br />

When the tag type is Gen2, user data equals to TID bank + user bank,<br />

and tag ID equals to EPC bank.<br />

Jeeeeeeee: Access to the password-protected tags (Omissible)<br />

Fixed to 8-digit hexadecimal number<br />

00000000 to FFFFFFFF<br />

Accesses the password-protected tags.<br />

This parameter is effective only for the EPC Class 1 Generation 2 tag type.<br />