10.07.2015 Views

OVERHEAD LINE SPLICES

OVERHEAD LINE SPLICES

OVERHEAD LINE SPLICES

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DISTRIBUTION CONNECTORSVERSAtile ALUMINUM COMPRESSION TERMINALTYPE VCEL• For use with either VERSA-CRIMP ® or conventional compressiontools.• For size-for-size replacements for original equipment set screwmechanical lugs, when recommended by the equipment manufacturer.• UL listed for both concentric and compact aluminum and concentriccopper conductor.• Meets NEMA CC3-1973 Class A performance on aluminumconcentric conductor.• Color coded end plugs for easy die selection (see page DF-16).Material:Body—Aluminum Tin PlatedFactory inhibitedLISTED261LTWL1 3/4Fig. 2 Fig. 1SECTION DFALUMINUMVCELCATALOGNUMBERFIG.NO.VCEL02114S1 1DIMENSIONSALUMINUM OR COPPER CONDUCTOR VERSA-CRIMP PADINCHES (MM)CONVENTIONALTOOLING RANGEVERSA-CRIMPSYSTEM RANGETOOLTYPEBOLTDIA. L W TVCEL021516H1 1 1/0 Str. Al/Cu #8—1/0 Str. Al/Cu5/16VCEL02138H1 1 3/8VCEL022516H1 12/0 Str. Al/Cu #1—2/0 Str. Al/CuVC6VCEL02238H1 1 3/8(ALL)VCEL024516H1 15/164/0 Str. Al/Cu 2/0—4/0 Str. Al/CuVCEL02438H1 1 3/8VCEL030516H1 1300 MCM Al/Cu #4—300 MCM Al/CuVCEL03038H1 1 3/8VCEL035516H1 15/16350 MCM Al/Cu 250-350 MCM Al/CuVCEL03538H1 1 3/8VC63VCEL05038H1 13/8VC6FT500 MCM Al/Cu 2/0—500 MCM Al/CuVCEL05012H1 1 1/2VCEL05012H2 2 500 MCM Al/Cu 2/0—500 MCM Al/Cu 1/2VCEL06012H1 1 600 MCM AlVCEL06012H2 2 600 MCM AlVCEL07512H1 1 750 MCM AlVCEL07512H2 2 750 MCM Al400-600—MCM Al400—500 MCM Cu400-600—MCM Al400—500 MCM Cu500-750—MCM Al500 MCM Cu500-750—MCM Al500 MCM CuVC6FTAL9CU (90° RATED)APPROX.WT. EACHLBS. (KG)I.D.(INCHES)HIGH VOLTAGE APPLICATIONS—All Aluminum/Copper and Copper Lugs (VCEL, VACL, VHCL, VHCS and VCELC) arerated at 34.5KV. The other U.L. Listed compression connectors (VACS, VACT, VCCT, VHSS and VHS) have a maximumUL voltage requirement of less than 2000 volts, however Anderson recommends these connectors for applicationthrough 34.5 KV subject to manufacturers’ limitations for insulation material.For further information, contact factory.1/45/165/161/21/21/21/21-3/4(44.5)1-3/4(44.5)1-27/32(46.7)2-17/64(57.4)2-17/64(57.4)2-17/64(57.4)2-17/64(57.4)2-17/64(57.4)2-17/64(57.4)2-17/64(57.4)2-17/64(57.4)3-13/32(86.4)3-13/32(86.4)5-3/64(128.0)3-21/32(92.7)5-9/32(134.4)3-21/32(92.7)5-9/32(134.4)39/64(15.2)39/64(15.2)11/16(17.5)1(25.4)1(25.4)1(25.4)1(25.4)1(25.4)1(25.4)1(25.4)1(25.4)1-3/16(30.1)1-3/16(30.1)1-3/16(30.1)1-5/16(33.0)1-5/16(33.0)1-5/16(33.0)1-5/16(33.0)1/4(6.4)1/4(6.4)11/64(4.4)9/32(7.1)9/32(7.1)9/32(7.1)9/32(7.1)9/32(7.1)9/32(7.1)9/32(7.1)9/32(7.1)1/2(12.7)1/2(12.7)1/2(12.7)1/2(12.7)1/2(12.7)1/2(12.7)1/2(12.7).03(.01).03(.01).03(.01).12(.05).12(.05).11(.05).11(.05).10(.04).10(.04).10(.04).10(.04).20(.09).20(.09).30(.13).28(.13).40(.18).25(.11).36(.16).403.403.403.453.453.562.562.656.656.711.711.844.844.928.928.9281.0311.031DF1DF-1HUBBELL ® Power Systems April 2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!