10.07.2015 Views

OVERHEAD LINE SPLICES

OVERHEAD LINE SPLICES

OVERHEAD LINE SPLICES

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DISTRIBUTION CONNECTORSSECTION DFVERSAtile COPPER COMPRESSION TERMINALTYPE VHCS(SHORT BARREL)• For use with either VERSA-CRIMP ® or conventionalcompression tools.• For copper stranded conductor only.• Color coded bands for easy die selection.• Material: Copper Tin Plated• Refer to page DF-31 for tool & die information.COPPERVHCSLISTED261LCATALOGNUMBERNO.PADHOLESVHCS614 1COPPER CONDUCTORCONVENTIONALTOOLINGVHCS6516 1 #6 Str. #6 Str.5/16VHCS614B 2 1/4VHCS414 1Refer to page DF-31 for recommended tool and die information.VERSA-DIMENSIONS INCHES (MM)VERSA-CRIMP ®SYSTEM RANGECRIMP ®TOOLTYPEPADBOLTDIA. L B W C TVC6350VHCS438 1 #4 Str. #4 Str.3/8VHCS414B 2 1/4VHCS214 1VHCS2516 1 #2 Str. #6–#2 Str.5/16VHCS238 1 3/8VHCS1516 1VC6VHCS138 1 #1 Str. #6–#1 Str. (ALL) 3/8VHCS1516B 2 VC7 5/16(ALL)VHCS1014 11/41/41/45/16VHCS10516 1 5/161/0 Str. #6–1/0 Str.VHCS1038 1 3/8VHCS1012 1 1/21/41-13/16(46.04)1-13/16(46.04)2-5/16(58.72)1-7/8(47.62)2-1/16(52.37)2-3/4(69.85)2(50.8)2-1/16(52.37)2-1/8(53.98)2-1/8(53.98)2-3/16(55.56)3(76.2)2-1/8(53.98)2-3/16(55.56)2-5/16(58.72)2-9/16(65.1)13/16(20.64)13/16(20.64)7/8(22.22)7/8(22.22)7/8(22.22)1/2(12.7)1/2(12.7)1/2(12.7)1/2(12.7)5/8(15.88)1/2(12.7)5/8(15.88)11/16(17.46)3/4(19.05)——5/8(15.88)——5/8(15.88)—————7/8(22.22)————1/16(1.59)1/16(1.59)1/8(3.18)1/8(3.18)1/16(1.59)1/8(3.18)1/8(3.18)1/8(3.18)1/8(3.18)APPROX.WT. EACHLBS. (KG).016(.007).016(.007).026(.011).02(.009).02(.009).032(.014).033(.015).033(.015).042(.019).037(.017).037(.017).064(.029).047(.021).047(.021).047(.021).047(.021)I.D.(INCHES).198.198.198.246.246.246.306.306.306.358.358.358.393.393.393.393Continued on next page.DF19HIGH VOLTAGE APPLICATIONS—All Aluminum/Copper and Copper Lugs (VCEL, VACL, VHCL, VHCS and VCELC) arerated at 34.5 KV. The other U.L. Listed compression connectors (VACS, VACT, VCCT, VHSS and VHS) have a maximumUL voltage requirement of less than 2000 volts, however Anderson recommends these connectors for applicationthrough 34.5 KV subject to the manufacturers’ limitations and recommendations for the insulation material.For further information, contact factory.DF-19HUBBELL ® Power Systems April 2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!