10.07.2015 Views

OVERHEAD LINE SPLICES

OVERHEAD LINE SPLICES

OVERHEAD LINE SPLICES

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DB18COPPERVHSS<strong>OVERHEAD</strong> <strong>LINE</strong> <strong>SPLICES</strong>-CUCOMPRESSIONVERSAtile COMPRESSION SPLICEMINIMUM TENSIONSTANDARD LENGTH• ANSI C119.4, minimum tension, Class 3 connector (5%of conductor breaking strength)• For use with either VERSA-CRIMP ® or conventionalcompression tools• For copper stranded conductor, only• Color coded bands for easy die selectionDLMaterial: Copper—Tin platedLISTED261LProduct Data & Conductor SizeCOPPER CONDUCTORVERSA-CRIMPDIMENSIONSINCHES (MM)CATALOGNUMBERCONVENTIONALWIRE SIZEVERSA–CRIMPSYSTEM RANGETOOLTYPEL DVHSS6 #6 Str. #6 Str.1-3/413/16VC6350(44.45)(20.64)VHSS4 #4 Str. #4 Str.VC65001-3/413/16(44.45)(20.64)VHSS2 #2 Str. #6–#2 Str.1-7/87/8(47.62)(22.22)VHSS1 #1 Str. #6-#1 Str.1-7/87/8(47.62)(22.22)1-7/87/8VHSS10 1/0 Str. #6-1/0 Str.(47.62)(22.22)VC6215/16VHSS20 2/0 Str. #4-2/0 Str.(ALL)(50.8)(23.81)2-1/81VHSS30 3/0 Str. #2-3/0 Str.VC7(53.98)(25.4)(ALL)2-1/81VHSS40 4/0 Str. #1-4/0 Str.(53.98)(25.4)VHSS250 250 MCM 1/0-250 MCM2-1/41-1/16(57.15)(26.97)VHSS300 300 MCM 2/0-300 MCM2-1/41-1/16(57.15)(26.97)2-3/81-1/8VHSS350 350 MCM 3/0-350 MCM VC6-3(60.32)(28.58)VC72-1/21-3/16VHSS400 400 MCM 4/0-400 MCMVC6FT(63.5)(30.16)VC7FT2-7/81-3/8VHSS500 500 MCM 4/0-500 MCMVC8**(73.02)(34.92)VHSS600 600 MCM 250-600 MCM2-7/81-3/8VC6FT(73.02)(34.92)VC7FTVHSS750 750 MCM 500-750 MCMVC8**I.D.(INCHES)OCTOBER 2012ANDERSON HUBBELL ® POWER SYSTEMS FARGO ®3-3/8(85.72)1-5/8(41.28)APPROX.WT. EACHLBS. (KG).02(.01).026(.01).04(.018).052(.023).057(.025).065(.029).094(.042).094(.042).12(.054).14(.063).17(.077).31(.14).32(.14).41(.19).54(.24)Refer to page DB-23 for recommended tool and die information.**Type VC8 compression tool crimping range is 500-1500 MCM Cu.HIGH VOLTAGE APPLICATIONS—All Aluminum/Copper and Copper Lugs (VCEL, VACL, VHCL, VHCS and VCELC) are rated at 34.5 KV. The other U.L. listedcompression connectors (VACS, VACT, VCCT, VHSS and VHS) have a maximum UL voltage requirement of less than 2000 volts, however Anderson recommendsthese connectors for application through 34.5 kV subject to manufacturers’ limitations for insulation material. For further information, contactfactory..198.246.306.358.393.443.490.547.595.650.700.762.834.9231.030

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!