10.07.2015 Views

OVERHEAD LINE SPLICES

OVERHEAD LINE SPLICES

OVERHEAD LINE SPLICES

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SECTION DFDISTRIBUTION CONNECTORSDF20CATALOGNUMBERNO.PADHOLESVHCS20516 1TYPE VHCS COPPER COMPRESSION TERMINAL (continued)COPPER CONDUCTORCONVENTIONALTOOLINGVHCS2038 1 3/82/0 Str. #4-2/0 Str.VHCS2012 1 1/2VHCS2012BN 2 1/2VHCS30516 1VHCS3038 1 3/83/0 Str. #2-3/0 Str.VHCS3012 1 1/2VHCS4012 1 4/0 Str. #1-4/0 Str.VC6(ALL)1/2VHCS4012BN 2VC7(ALL)1/2VERSA-DIMENSIONS INCHES (MM)VERSA-CRIMP ®SYSTEM RANGECRIMP ®TOOLTYPEPADBOLTDIA. L B W C T5/162-5/16(58.74)—5/16VHCS30516B 2 5/16VHCS4038 1VHCS250516 1VHCS25038 1 3/8VHCS25012 1 250 MCM 1/0-250 MCM1/2VHCS25038B 2 3/8VHCS25012BN 2 1/2VHCS300516 13/85/16VHCS30012 1 1/2300 MCM 2/0-300 MCMVHCS30038B 2 3/8VHCS30012BN 2 1/25/16VHCS35038VHCS3501211 350 MCM 3/0-350 MCMVC63VC7VC6FTVC7FT3/81/2VHCS35012BN 2 1/22-7/16(61.92)2-11/16(68.26)4-1/2(114.3)2-7/16(61.92)2-1/2(63.5)2-3/4(69.85)3-1/4(82.55)2-5/8(66.68)2-7/8(73.02)4-11/16(119.06)2-13/16(71.44)2-7/8(73.02)3(76.2)3-11/16(93.66)4-13/16(122.24)3(76.2)3-1/16(77.77)3-3/4(95.25)4-7/8(123.82)3-1/8(79.38)3-3/16(80.96)5(127.0)15/16(23.81)1(25.4)1(25.4)1-1/16(26.97)1-1/16(26.97)1-1/8(28.58)13/16(20.64)15/16(23.81)1(25.4)1-1/8(25.58)1-3/16(46.04)1-5/16(33.32)——1-3/4(44.45)———7/8(22.22)——1-3/4(44.45)———1 1/16(26.97)1 3/4(44.45)——1 1/16(26.97)1 3/4(44.45)——1-3/4(44.45)1/8(3.18)1/8(3.18)1/8(3.18)3/16(4.76)3/16(4.76)3/16(4.76)LISTED261LAPPROX.WT. EACHLBS. (KG).059(.027).059(.027).059(.027).079(.036).073(.033).073(.033).073(.033).10(.045).093(.042).093(.042).13(.059).13(.059).13(.059).13(.059).16(.072).16(.072)I.D.(INCHES).443.443.443.443.490.490.490.490.547.547.547.595.595.595.595.595.15(.068) .650.15(.068).650.19(.086).650.19(.086).650.18(.082).700.18(.082).700.24(1.09).700Refer to page DF-31 for recommended tool and die information.Continued on next page.HIGH VOLTAGE APPLICATIONS—All Aluminum/Copper and Copper Lugs (VCEL, VACL, VHCL, VHCS and VCELC) arerated at 34.5 KV. The other U.L. Listed compression connectors (VACS, VACT, VCCT, VHSS and VHS) have a maximumUL voltage requirement of less than 2000 volts, however Anderson recommends these connectors for applicationthrough 34.5 KV subject to manufacturers’ limitations for insulation material.For further information, contact factory.DF-20April 2012HUBBELL ® Power Systems

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!