10.07.2015 Views

OVERHEAD LINE SPLICES

OVERHEAD LINE SPLICES

OVERHEAD LINE SPLICES

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SECTION DFDISTRIBUTION CONNECTORSTYPE VHCL Copper Compression Terminal (continued)LISTED261LDF24COPPER CONDUCTOR VERSA-DIMENSIONS INCHES (MM)CATALOGNUMBERNO.PADHOLESCONVEN-TIONALTOOLINGVERSA-CRIMP ®SYSTEM RANGECRIMP ®TOOLTYPEPADBOLTDIA. L B W C TVHCL40012 11/24-5/16(109.52)—3/16VHCL40034 1 3/44-15/16(4.76)(125.41)—400 MCM 4/0-400 MCM2-1/8 1-3/8(53.98) (34.92)VHCL40038B 2 3/85-1/161-1/16(128.57)(26.97)VHCL40012BN 2 1/26-1/161-3/4(153.97)(44.45)3/16VHCL50038 1VC63 3/84-1/2(4.76)VC7(114.3)—VHCL50012 1VC6FTVC7FT 1/24-5/8(117.48)—VHCL50058 1 5/84-3/4(120.65)—1/4500 MCM 4/0-500 MCM2-1/4 1-1/2(6.35)(57.15) (38.1)VHCL50038B 2 3/85-1/41-1/16 7/32(133.35)(26.97) (5.56)VHCL50012BN 2 1/26-1/4(158.75)1-3/4(44.45)VHCL50034B 2 3/46-3/4(171.45)1-3/4(44.45)7/32(5.56)VHCL60012 11/25-3/16(131.76)—600 MCM 250-600 MCM2-11/16 1-11/161/4(68.26) (42.86)(6.35)VHCL60012BN 2 VC6FT 1/26-13/161-3/4(173.04)(44.45)VC7FTVHCL75058 1VC8** 5/86-1/4(158.75)—750 MCM 500-750 MCM2-7/8 1-15/161/4(73.02) (49.21)(6.35)VHCL75012BN 2 1/27-5/161-3/4(185.7)(44.45)VHCL80012BN 2 800 MCM 500-800 MCM1/27-1/8(180.98)2-15/16(74.61)2(50.8)1-3/4(44.45)5/16(7.92)VHCL100058 15/86-11/18(169.86)—VC8**VHCL100012B 2 1000 MCM 750-1000 MCM1/27 3 2-3/16 1-1/4 5/16(177.8) (76.2) (55.56) (31.75) (7.92)VHCL100012BN 2 1/27-9/16(192.09)1-3/4(44.45)Refer to page DF-32 for recommended tool and die information.APPROX.WT. EACHLBS. (KG).36(.163).41(.18).42(.19).51(.23).48(.218).48(.218).48(.218).56(.254).56(.254).74(.34).73(.33).96(.43).94(.426).98(.444).99(.449)1.45(.658)1.65(.748)1.65(.748)I.D.(INCHES)**VC8 tool crimping range is 500-1500 MCM Cu.HIGH VOLTAGE APPLICATIONS—All Aluminum/Copper and Copper Lugs (VCEL, VACL, VHCL, VHCS and VCELC) arerated at 34.5 KV. The other U.L. Listed compression connectors (VACS, VACT, VCCT, VHSS and VHS) have a maximumUL voltage requirement of less than 2000 volts, however Anderson recommends these connectors for applicationthrough 34.5 KV subject to manufacturers’ limitations for insulation material.For further information, contact factory..762.762.762.762.834.834.834.834.834.834.923.9231.0301.0301.0511.1721.1721.172DF-24April 2012HUBBELL ® Power Systems

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!