<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> Appendices | en 107Report Index Receiver outputPOINT WATERFLOW DIRTY RESTORE 25 dd/dd tt:tt ql ACCT aaaa ANALOG RESTORE+++ ACCT aaaa AREA=1 POINT=zzzPOINT SUPERVISO Y DIRTY RESTORE 26 dd/dd tt:tt ql ACCT aaaa ANALOG RESTORE+++ ACCT aaaa AREA=1 POINT=zzzPOINT MONITOR DIRTY RESTORE 27 dd/dd tt:tt ql ACCT aaaa FIRE TBL RESTOR+++ ACCT aaaa AREA=1 POINT=zzzPOINT FIRE DISABLE RESTORE 28 dd/dd tt:tt ql ACCT aaaa FIRE TBL RESTOR+++ ACCT aaaa AREA=1 POINT=zzzPOINT WATERFLOW DISABLE RESTORE 29 dd/dd tt:tt ql ACCT aaaa FIRE TBL RESTOR+++ ACCT aaaa AREA=1 POINT=zzzPOINT SUPERVISORY DISABLE RESTORE 30 dd/dd tt:tt ql ACCT aaaa FIRE TBL RESTOR+++ ACCT aaaa AREA=1 POINT=zzzPOINT MONITOR DISABLE RESTORE 31 dd/dd tt:tt ql ACCT aaaa FIRE TBL RESTOR+++ ACCT aaaa AREA=1 POINT=zzzSYSTEM IN TEST 40 dd/dd tt:tt ql ACCT aaaa WALK TEST START+++ ACCT aaaa AREA=1 ID=uuuSYSTEM IN TEST RESTORE 41 dd/dd tt:tt ql ACCT aaaa WALK TEST END+++ ACCT aaaa AREA=1 ID=uuuSILENCE 42 dd/dd tt:tt ql ACCT aaaa SENSOR RESET+++ ACCT aaaa AREA=0 ID=uuu RELAY#=0FIRE DRILL 43 dd/dd tt:tt ql ACCT aaaa FIRE WALK START+++ ACCT aaaa AREA=1 ID=uuuFIRE DRILL RESTORE 44 dd/dd tt:tt ql ACCT aaaa FIRE WALK END+++ ACCT aaaa AREA=1 ID=uuuSYSTEM RESET 45 dd/dd tt:tt ql ACCT aaaa SENSOR RESET+++ ACCT aaaa AREA=1 ID=uuu RELAY#=0LOW BATTERY 46 dd/dd tt:tt ql ACCT aaaa BATTERY LOWLOW BATTERY RESTORE 47 dd/dd tt:tt ql ACCT aaaa BATTERY RESTOREAC FAIL 48 dd/dd tt:tt ql ACCT aaaa AC FAILUREAC FAIL RESTORE 49 dd/dd tt:tt ql ACCT aaaa AC RESTORALAUTO TEST 50 dd/dd tt:tt ql ACCT aaaa TEST REPORTOFF NORMAL AT TEST 51 dd/dd tt:tt ql ACCT aaaa TEST-OFF NORMALPHONE 1 TROUBLE 52 dd/dd tt:tt ql ACCT aaaa PHONE LINE FAIL+++ ACCT aaaa PHONE LINE=1PHONE 1 RESTORE 53 dd/dd tt:tt ql ACCT aaaa PHONE RESTORAL+++ ACCT aaaa PHONE LINE=1PHONE 2 TROUBLE 54 dd/dd tt:tt ql ACCT aaaa PHONE LINE FAIL+++ ACCT aaaa PHONE LINE=2<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!