11.07.2015 Views

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> Overview | en 17– Select the next larger standard battery for the system.If the results show a requirement for a battery over 40 Ah, reduce the existing load or add anexternal regulated fire protective signaling power supply.2.2.12Compatible devicesDeviceD7030 Eight Point LEDAnnunciatorD7030X Eight Point LEDAnnunciatorD7030X‐S2 Eight Point LEDAnnunciatorD7030X‐S8 Eight Point LEDAnnunciatorD7032 Eight Point LEDAnnunciator ExpanderFMR‐7033 Alphanumeric LCDKeypadFPC‐7034 Four Point ExpanderD7035/B Octal Relay ModuleFMR‐7036 <strong>Fire</strong> AnnunciatorKeypadFPP‐RNAC‐8A‐4C Remote NACPower SupplyFunctionIdentifies the location of a fire alarm for up to eight zonesallowed per system.Identifies the location of a fire alarm for up to eight zonesallowed per system.An eight zone LED annunciator, of which two zones arereserved for supervisory functions. It has Power andTrouble LEDs plus eight zone LEDs that can be labeledindividually.An eight-zone LED annunciator, of which all eight zones arereserved for supervisory functions. It has Power andTrouble LEDs plus eight-zone LEDs that can be labeledindividually.Attaches to a D7030X and identifies the location of a firealarm for eight additional zones.The FMR‐7033 LCD Keypad combines remote annunciatorand controller functions for the FPD‐7024. Up to fourkeypads can be connected.Allows the FPD‐7024 <strong>Control</strong> Panel to support fouradditional loops. The FPC‐7034 plugs into the control paneland provides four Class B, Style 4 loops that are identicalin characteristics to the loops on the control panel. OneFPC‐7034 is allowed per system.Provides eight Form C relay outputs for addition to thesystem. The outputs are programmable and can beactivated by system events. Each output operatesindependently of the other seven outputs for completeflexibility. The D7035 connects to the option bus; up totwo are allowed per system. The D7035B comes installedon a mounting skirt.For required enclosure modification, see also the D7035Installation Guide.Establishes the location of a fire alarm.Adds four NFPA 72 Class B, Style Y Notification ApplianceCircuits through the option bus and is supervised by thecontrol panel. The FPP‐RNAC‐8A‐4C connects to the optionbus of the FPD‐7024 control panel and up to four areallowed per system.<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!