<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> <strong>Control</strong> Panel Programming | en 91If no devices are connected on Bus A, the following window appears. Otherwise an errormessage appears.PROGRAM MUX1- NORMAL2- FASTSelect normal programming to add one or two devices. Select fast programming to programlarger quantities of identical devices to sequential addresses.Normal ProgrammingIf normal programming is selected, the following menu appears allowing selection of thedevice type being programmed:DEVICE TYPE ( )0- NO DEVICE2- SINGLE INPUT3- I/O MODULE4- MUX SMOKE5- SMOKE W/FRZ6- DUAL INPUT7- OCTAL INPUTDescriptionModel0- NO DEVICE2- SINGLE INPUT D7044/M, D7045, FMM-7045, D7052(Class A)3- I/O MODULE D70534- MUX SMOKE D7050, D7050TH, D3435- SMOKE W/FRZ Not Used6- DUAL INPUT D7052(Class B)7- OCTAL INPUT D7042Enter the number that corresponds with the device you are adding, or select 0 if you areremoving a device. When the device type is selected, the following window appears:POINT NUMBER(009 - 255) 009Enter the address of the point being added, and press [#/Enter]. The display asks you toattach the device being programmed to the terminals for MUX bus A (see the followingwindow). You can simply hold the device wires on the terminals for the few seconds it takesto program. The programming operation retries up to three times if the device does notconnect right away.POINT NUMBER 009ATTACH DEVICEThen, the display automatically shows:POINT NUMBER 009PROGRAMMINGIf the device added is an I/O module, you are asked to enter the four zones to control the relayoutput, just as for other relay devices:OUTPUT ZONE A: _______(00 - 63): _______Enter the first zone (00 to 63) you want to assign to this output and press [#/Enter]. A similardisplay for Zone B, C and D appears allowing up to four zones to control this output. When allfour zones are assigned, the previous window appears. It confirms the programming operationand returns to the previous menu.POINT NUMBER 009PROGRAMMED<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!