11.07.2015 Views

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

68 en | <strong>Control</strong> Panel Programming <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>Pressing [Drill] retrieves the next point. For instance, if you are programming Point 2 and youpress [Drill], you retrieve the setting for Point 3.Pressing [History] retrieves the previous point. For instance, if you are programming Point 2and you press [History], you return to the setting for Point 1.Assigning point functionsShortcut: 0-PROG, 4-PROG INPUTS, 1-POINT NUMBERThis feature assigns each point to one point function. A point function is a set ofcharacteristics that you can assign to selected points. There are 16 point functions to choosefrom.For more information about point functions, see Point function, 70. For the limitations whenassigning points to point functions that were programmed with a response time other thanFast, see Loop response, 72.Enter the point number you wish to program and press [#/Enter]. The display scrolls throughthe PROG INPUT options.Press [0/Prog] to select FUNCTION. The following window appears:POINT FUNC. (___)(01 - 16):_______Enter the function number you wish to assign to the point and press [#/Enter]. The existingsetting is shown in parentheses on the first line. After you assign a point function, the previouswindow appears.<strong>Alarm</strong>/Trouble statusShortcut: 0-PROG, 4-PROG INPUTS, 1-POINT NUMBERThis feature allows you to program the system response to an open loop condition. A shortedloop always causes an alarm condition.For acceptable programming selections for UL864 9 th edition Listed applications, seeProgramming features for UL864, 49.ALARM: A point in an open circuit state causes an alarm.TROUBLE: If a point is in an open circuit state, the system responds with a trouble condition.Enter the point number you wish to program and press [#/Enter]. The display scrolls throughthe PROG INPUT options.Press [1] to select ALARM/TROUBLE. The following window appears:OPEN STATUS (__)1- ALARM2- TROUBLEPress [1] to select ALARM on open loop and ALARM on shorted loop or [2] to select TROUBLEon open loop and ALARM on shorted loop. The previous window appears. The existing settingis shown in parentheses on the first line.Output zonesShortcut: 0-PROG, 4-PROG INPUTS, 1-POINT NUMBEREnter the point number you wish to program and press [#/Enter]. The display scrolls throughthe PROG INPUT options.Press [2] to select OUTPUT ZONE. The following window appears:2012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!