<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> System Operation | en 47ZoneCondition61 General Waterflow (Non-silenceable). Active when any waterflow alarm is present.62 General Trouble. Active while any system trouble is present, not active in test andprogramming modes.63 General <strong>Alarm</strong>, Waterflow (non-silenceable). Active while any alarm, includingsupervisory, is present. Remains active even while system is silenced.Table 6.3: Pre-assigned zones6.6Personal Identification Numbers (PINs)The personal identification number (PIN) is the four digit code users enter at the keypad togain access to the system. A PIN can be assigned to each User Number. The User Numberidentifies each person using the system. There are 16 possible User Numbers (00 to 15). Usercodes 00 to 99 are available with the installation of a D7039 Multiple Expansion Module. TheAuthority Level assigned to each User Number determines which functions each user canperform.Your system can have up to 100 different PINs, each four digits long. There is one PIN for eachUser Number. Attempting to assign the same PIN to multiple User Numbers results in thethree-beep error tone, and the change is not made.User Number 00 is designated as a Programmer’s Code. It can be used to silence alarms,reset, disable, and program the unit.User Number 00 is shipped from the factory with the sequence of 9876. Change this code toone of your personal preference. It is automatically assigned the highest authority. Neverprogram PINs with common sequences such as 1111, 1234, or 2468 because they are easilyviolated.Authority levels are assigned to PINs to determine which functions each user can perform.For a description of the four authority levels, see the following table:PIN authority levelMaximum (1)Medium (2)Minimum (3)None (0)Allowed operationsAll control panel operations, including programming, and disableSystem test modes, fire drill, reset, silence, view historySilence, view historyNoneTable 6.4: PIN authority levels6.7Communicator OperationThe FPD-7024 contains an integrated communicator that can be optionally enabled to sendreports to a monitoring station. When enabled, operation of the communicator is fullyautomatic.iNotice!You must enable and configure the communicator before it works. The communicator andphone line monitors are disabled in the default factory configuration.<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!