11.07.2015 Views

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

18 en | Overview <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>DeviceD7039 Multiplex ExpansionModuleD7042/B Eight‐Input RemoteModuleD7048/B Octal Driver ModuleFMM-7045 MUX Pull StationD7044 MUX Single InputModuleD7044M MUX Mini ContactModuleD7052 MUX Dual Input <strong>Fire</strong>D7053 MUX I/O Module <strong>Fire</strong>D7050/TH MUX Smoke DetectorDX4020 / B420 modelsITS‐DX4020‐GFunctionProvides either 2 two-wire (Class B, Style 4) multiplexbuses or 1 four-wire (Class A, Style 6) multiplex bus. InClass A mode, up to 120 addressable points can be added.In Class B Mode, up to 247 addressable points can beadded. The D7039 connects directly to the control panel.One is allowed per system.Provides eight Class B, Style 4 input points. Connect up to15 modules to MUX Bus A, and 15 on MUX Bus B. TheD7042 is powered by 12 VDC supplied by the option buspower terminals, in addition to the two‐wire dataconnection. The D7042 can not be used on a signal linecircuit (SLC) configured for Class A, Style 6 operation.Provides eight open‐collector transistor outputs foraddition to the FPD‐7024 <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> panels. Itconnects to the control panels through the option bus.UL Listed fire alarm initiating device.Connects a normally‐open contact device to the multiplexbus of the FPD‐7024 with a supervised local loop. TheD7044 draws operating power from the FPD‐7024.Connects a contact device to the multiplex bus of theFPD‐7024 with a supervised input loop. The D7044 drawsoperating power from the FPD‐7024.Connects to the multiplex bus of the FPD‐ 7024 andprovides two supervised input zones for connectingconventional normally-open inputs. The D7052 drawsoperating power from the FPD‐7024.Connects to the multiplex bus of the FPD‐7024 andimplements a supervised local loop, and a Form C relayoutput. Up to 20 modules can be connected to each MUXbus. The D7053 draws operating power from theFPD‐7024.The D7050/TH is a photo-electric smoke detector with aheat option. It connects to the multiplex bus of theFPD‐7024. The D7050 draws operating power from theFPD‐7024.The Conettix DX4020 and B420 models are communicationdevices that manages secure, two-way IP communicationsover Ethernet networks.The ITS-DX4020-G enables two-way IP or dialedcommunications over a commercial GPRS/GSM network.Typical applications are event reporting to a centralmonitoring station and remote access to <strong>Bosch</strong> controlpanels.2012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!