11.07.2015 Views

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

20 en | <strong>Fire</strong> Safety <strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong>3<strong>Fire</strong> SafetyDanger!No fire detection device or system is 100% foolproof.This fire alarm system can provide early warning of a developing fire. Such a system, however,does not ensure protection against property damage or loss of life resulting from a fire. Anyfire alarm system can fail to warn for any number of reasons (such as smoke not reaching adetector that is behind a closed door).iNotice!This system must be regularly tested (when installed, when modified, and at least annuallythereafter) to ensure continued performance.When considering detectors for residential applications, refer to NFPA Standard 72, TheNational <strong>Fire</strong> <strong>Alarm</strong> Code. This standard is available at a nominal cost from: The National <strong>Fire</strong>Protection Association, Batterymarch Park, Quincy, MA 02269.3.13.1.13.1.2Smoke detector layoutGeneral considerationsProper location of detection devices is one of the most critical factors in a fire alarm system.Smoke detectors should not be installed in dead air spaces or close to ventilating or airconditioning outlets because smoke can be circulated away from the detector. Locations nearair inlets are favored.Avoid areas subject to normal smoke concentrations such as kitchens, garages, or nearfireplaces.Do not install smoke detectors where normal area temperatures are above +100°F (+38°C) orbelow +32°F (0°C).Avoid areas of high humidity and dust concentrations.Place the edge of ceiling mounted detectors no closer than 4 in. (10 cm) from any wall.Place the top edge of wall-mounted detectors between 4 in. and 12 in. (10 cm and 30 cm)from the ceiling.For exact mounting information, refer to the instructions provided with the smoke detectors.Family residencesProviding a <strong>Fire</strong> Warning System: Most fire deaths occur in the home, especially duringsleeping hours. The minimum level of protection requires smoke detectors to be installedoutside of each separate sleeping area and on each additional story of the dwelling.iNotice!For added early warning protection, install detectors in all separate areas including the basement,bedrooms, dining room, utility room, furnace room, and hallways.For residential smoke detector locations, see the following figure:2012.08 | 04 | F01U008458 Installation and Operation Manual <strong>Bosch</strong> <strong>Security</strong> System, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!