11.07.2015 Views

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> <strong>Control</strong> Panel Programming | en 75ZonePre-Assigned Condition52 General <strong>Fire</strong> <strong>Alarm</strong> (non-silencing)53 General <strong>Fire</strong> <strong>Alarm</strong>, (silencing)54 Ground Start55 General Supervisory, (silencing)56 General Waterflow, (silencing)57 Communication Trouble58 General Supervisory <strong>Alarm</strong> (non-silencing)59 <strong>Alarm</strong> Verification60 AC Failed61 General Waterflow <strong>Alarm</strong> (non-silencing)62 General Trouble63 General <strong>Alarm</strong>, Waterflow Supervisory (non-silencing)Table 8.2: Pre-assigned zone quick referenceRemote NACsShortcut: 0-PROG, 5-PROG OUTPUTS, 1-NACsUse only with the FPP‐RNAC‐8A‐4C. The display scrolls through the NAC options. Press [2]for REMOTE 1, [3] for REMOTE 2, [4] for REMOTE 3, or [5] for REMOTE 4. One of thefollowing windows appears:REM EXP NAC #11 - NAC #12 - NAC #23 - NAC #34 - NAC #4orREM EXP NAC #21 - NAC #12 - NAC #23 - NAC #34 – NAC #4orREM EXP NAC #31 - NAC #12 - NAC #23 - NAC #34 - NAC #4orREM EXP NAC #41 - NAC #12 - NAC #23 - NAC #34 - NAC #4Press the number key that corresponds with the NAC you want to program. The display scrollsthrough the following selections:PROG NACs1- (reserved)2- CONFIGURATION3- ZONE ASSIGNSThe options for remote NACs are the same as for local NACs.Output Configuration:Steady: Programmed to turn on steadily for a fire alarm.Pulsing: Programmed to pulse for a fire alarm at 0.5 sec on and 0.5 sec off.California March: Output turns on for 0.25 sec and off for 0.25 sec.Temporal: Programmed to pulse for a fire alarm in Temporal 3.Zone Assignment: Assign each output up to four zones. ZONE A, B, C, or D (00 = disabled) (1to 63).Press the number key that corresponds to your selection. After you program the local NACs,the previous window appears.<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!