11.07.2015 Views

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

Fire Alarm Control Panels - Bosch Security Systems

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Fire</strong> <strong>Alarm</strong> <strong>Control</strong> <strong>Panels</strong> <strong>Control</strong> Panel Programming | en 69OUTPUT ZONE ZZZ(01 - 50):_______Press the number key that corresponds to your selection. ZZZ indicates the point beingprogrammed. The existing setting is shown on the second line. After you set up the outputzone, the previous window appears.VerificationShortcut: 0-PROG, 4-PROG INPUTS, 1-POINT NUMBERThis feature resets the detector once to determine if the alarm recurs before annunciating orsending a signal. The total delay introduced by this feature is equal to the smoke power resettime plus five seconds. <strong>Alarm</strong> verification cannot be selected for points that are configured asWATERFLOW or SUPERVISORY types.Enter the point number you wish to verify and press [#/Enter]. The display scrolls through thePROG INPUT options.Press [3] to select VERIFICATION. The following window appears:ALARM VERIF (ZZZ)_______: YES(1) NO(0)ZZZ indicates the point being programmed. The existing setting is shown on the second line.Press either [1] to verify or [0/Prog] to not verify. The previous window appears.LatchingShortcut: 0-PROG, 4-PROG INPUTS, 1-POINT NUMBERIf a zone is non-latching, the system resets the alarm status automatically (but does not resetsmoke power) when the input restores to the standby condition. Otherwise, the system mustbe manually reset.For acceptable programming selections for UL864 9 th edition Listed applications, seeProgramming features for UL864, 49.Enter the point number you wish to program and press [#/Enter]. The display scrolls throughthe PROG INPUT options.Press [4/◄] to select LATCHING. The following window appears:LATCHING? ZZZ:YES(1)NO(0)ZZZ indicates the point being programmed. The existing setting is shown on the second line.Press the number key that corresponds to your selection. Select YES for alarm.The previous window appears.Point descriptionShortcut: 0-PROG, 4-PROG INPUTS, 1-POINT NUMBERFor this feature, use the numeric keys to enter alphanumeric information to identify each input(such as initiating circuit). The system allows one 16-character description per input. Enter thepoint number you wish to program and press [#/Enter]. The display scrolls through the PROGINPUT options.Press [5] to select DESCRIPTION. The following window appears:PNT DSCRPTN ZZZ:<strong>Bosch</strong> <strong>Security</strong> System, Inc. Installation and Operation Manual 2012.08 | 04 | F01U008458

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!